Personalizing Bone Tumor Ablation: Decision Models from the University Hospital of Strasbourg.
Roberto Luigi Cazzato, Francois Severac, Dominik A Steffen, Matilde Mandolini, Sinan Orkut, Afshin Gangi
Department of Interventional Radiology, University Hospital of Strasbourg, 1, Place de l'Hôpital, 67000, Strasbourg, France. roberto-luigi.cazzato@chru-strasbourg.fr. · Department of Public Health Medicine, University Hospital of Strasbourg, 1, Place de l'Hôpital, 67091, Strasbourg, Cedex, France.
Key points
From the paper's conclusion- The experts-derived and the decision-tree models demonstrated comparable overall accuracy despite relying on the different decision-making. Prospective multicenter studies are required to determine which of these two approaches is more suited for implementation in clinical practice.
Abstract
PURPOSE: To describe the clinical decision-making underlying the selection of the percutaneous ablation modality for bone tumors. MATERIALS AND METHODS: Two experienced interventional radiologists designed in consensus a model for ablation modality selection. Consecutive patients with primary and metastatic bone tumors were retrospectively identified. Demographic, clinical, and imaging data were collected for each tumor. The dataset was randomly divided into a training set (618/926 tumors; 66.7%) and a test set (308/926 tumors; 33.3%). A decision-tree model derived from the training set and the model proposed by the experts were both verified on the test set. Models' performance was assessed. RESULTS: The decision-tree and the experts-based models achieved comparable accuracy (81.8% vs. 80.5%; p = 0.493). For cryoablation, the experts-based model demonstrated significantly higher sensitivity (94.0% vs. 87.5%, p = 0.008), whereas the decision-tree model showed significantly higher specificity (79.3% vs. 69.3%, p = 0.001). For radiofrequency ablation, the decision-tree model exhibited substantially higher sensitivity (35.8% vs. 7.5%, p < 0.001), while the experts-based model had higher specificity (98.4% vs. 93.7%, p = 0.004). Performance for interstitial laser ablation was comparable between the two models, with no significant differences in sensitivity (98.8% vs. 98.9%, p = 1) and specificity (94.1% vs. 95.0%, p = 0.500). CONCLUSION: The experts-derived and the decision-tree models demonstrated comparable overall accuracy despite relying on the different decision-making. Prospective multicenter studies are required to determine which of these two approaches is more suited for implementation in clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Percutaneous Cryoablation in Bone Tumors: Current Applications, Technical Considerations, Clinical Outcomes, and Future Perspectives.Cureus · 2026
- Using Decision Tree to Predict Cancer-Specific Mortality in Patients with Clear Cell Renal Cancer Treated with Nephrectomy.Cancers · 2026
- Structured ACR Bone-RADS Versus Unstructured Assessment of Bone Tumors on Radiographs: A Multicenter, Multireader Study Across Experience Levels.Journal of the American College of Radiology : JACR · 2026
- Reevaluation of the Bayesian network model to support immunotherapy decision-making in recurrent/metastatic head and neck squamous cell carcinoma.International journal of computer assisted radiology and surgery · 2026
- Sequential Application of the Birmingham Atypical Cartilage Tumor Imaging Protocol and Radiological Aggressiveness Score in Long-Bone Intramedullary Cartilage Tumors: A Retrospective Cohort Study.Diagnostics (Basel, Switzerland) · 2026
- EFFICACY AND SAFETY OF PERCUTANEOUS CRYOABLATION FOR DESMOID TUMORS: PROTOCOL FOR A SYSTEMATIC REVIEW AND META-ANALYSIS.Acta ortopedica brasileira · 2026