From the paper's conclusion
  • Implant selection must transcend market trends, prioritizing a personalized approach. While textured surfaces may offer mechanical advantages, particularly in anatomical devices, their indication should be balanced against regulatory considerations, local availability, and patient preference. For round implants, careful risk-benefit consideration is also recommended. Success depends on aligning surface technology with precise surgical planes and requiring strict asepsis. Further long-term studies are needed to better understand surface-immune system interactions.

Abstract

BACKGROUND: Breast augmentation remains a leading esthetic procedure, with an ongoing debate regarding smooth versus textured implant surfaces. While texturing enhances stability and reduces capsular contracture, it is associated with an increased risk of BIA-ALCL. Conversely, smooth devices introduce other risks such as increased mobility and bottoming-out deformities. Adding further complexity, systemic symptoms described as breast implant illness (BII) have been reported across all implant types, and their relationship to specific surface topographies unclear. This review synthesizes current evidence regarding the safety and performance of different surfaces. METHODS: A systematic review was conducted across PubMed, Web of Science, and Scopus following PRISMA guidelines. Data extraction included patient demographics, surgical techniques, and outcomes such as capsular contracture, hematoma, infection, bottoming-out deformity, seroma, reoperation, and BIA-ALCL. Meta-analyses were performed using random-effects models to calculate risk ratios with 95% confidence intervals. RESULTS: Twelve studies involving 17726 patients were included. Textured implants showed a significantly lower risk of bottoming out (RR = 0.10; 95% CI, 0.03-0.33; p < .001). No significant differences were observed for capsular contracture, infection, seroma, or reoperation rates. Subpectoral/retropectoral placement significantly reduced infection rates compared to prepectoral placement (p < .001). The pooled reoperation rate for clinical complications was significantly higher than reoperations performed at the patient's request (p = .015). No BIA-ALCL cases were detected within the study period. CONCLUSIONS: Implant selection must transcend market trends, prioritizing a personalized approach. While textured surfaces may offer mechanical advantages, particularly in anatomical devices, their indication should be balanced against regulatory considerations, local availability, and patient preference. For round implants, careful risk-benefit consideration is also recommended. Success depends on aligning surface technology with precise surgical planes and requiring strict asepsis. Further long-term studies are needed to better understand surface-immune system interactions. LEVEL OF EVIDENCE III: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers