Three-Dimensional Surface Imaging in Postoperative Volumetric Assessment of Implant-Only and Composite Breast Augmentation.
Isil Akgun Demir, Naci Celik, Sevgili Kurt
Department of Plastic, Reconstructive and Aesthetic Surgery, Istanbul Atlas University, Istanbul, Turkey. · Department of Plastic, Reconstructive and Aesthetic Surgery, Istanbul Atlas University, Istanbul, Turkey. drnacicelik@gmail.com.
Key points
From the paper's conclusion- Vectra XT showed stable postoperative volumetric tracking after implant-only breast augmentation and may also be useful for follow-up assessment in composite cases. In composite augmentation, variations from the theoretically expected volume appear to reflect biological variability in fat graft retention and anatomical footprint rather than instability of the imaging system.
Abstract
BACKGROUND: Three-dimensional (3D) surface imaging is better validated for postoperative volume assessment in implant-only augmentation than in composite breast augmentation (CBA). In CBA, the extent to which anatomical features and biological variability contribute to volumetric deviation remains insufficiently defined. METHODS: This retrospective study included 94 patients (188 breasts) who underwent either implant-only augmentation (Group 0) or composite augmentation with fat grafting (Group 1). Breast volumes were measured with the Vectra XT system preoperatively and at 3 and 6 months postoperatively. Net postoperative volume gain was compared with implant volume, and both signed and absolute volumetric deviations were calculated. Mixed-effects and generalized estimating equation models were used to identify factors associated with deviation magnitude and direction. RESULTS: Six-month postoperative breast volume was greater in the composite group than in the implant-only group (p = 0.0186). Signed volumetric deviation was significantly more negative in composite cases (p < 0.001). A net volume gain smaller than implant volume was observed in 20.9% of composite breasts and 48.0% of implant-only breasts (p < 0.001). Among breasts with a net gain smaller than implant volume, the median deviation magnitude was similar in both groups, at approximately 22 mL. Greater breast base width was independently associated with increased absolute volumetric deviation (p = 0.005), whereas intersternal distance influenced deviation direction but not deviation magnitude. Postoperative BMI change was also independently associated with signed volumetric deviation (p < 0.001). Agreement between 3- and 6-month measurements was high (ICC = 0.95). CONCLUSIONS: Vectra XT showed stable postoperative volumetric tracking after implant-only breast augmentation and may also be useful for follow-up assessment in composite cases. In composite augmentation, variations from the theoretically expected volume appear to reflect biological variability in fat graft retention and anatomical footprint rather than instability of the imaging system. LEVEL OF EVIDENCE III: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Automatic three-dimensional surface imaging with chest computerized alignment for preoperative breast volume evaluation.Journal of plastic, reconstructive & aesthetic surgery : JPRAS · 2026
- Comparison of 3D-Surface Imaging and MRI for Breast Volume Measurement.Aesthetic plastic surgery · 2026
- Autologous Fat Grafting for Breast Augmentation and Breast Remodeling: A Systematic Review and Meta-analysis of Complications, Radiologic Outcomes, Graft Retention, and Patient-Reported Satisfaction.Aesthetic surgery journal · 2026
- BREAST-V Versus MRI for Breast Volume Assessment Before and After Breast Asymmetry Surgery: Good Preoperative Association but Limited Postoperative Interchangeability.Aesthetic surgery journal · 2026
- Evaluation of the efficacy and safety of breast augmentation using implants combined with autologous fat grafting: a retrospective study of 219 cases.Gland surgery · 2026
- Retrospective Validation of a Tissue-Preserving Breast Augmentation Approach: From Native Tissue Geometry to Surgical Practice.Aesthetic surgery journal · 2026