The effect of three dimensional-printed guides on assisting rotational axis localization of hinged external fixator in the surgery for elbow terrible triad injury.
Huizhi Chen, Tianyu Zhao, Hongwei Gao, Pengcheng Ma
Shandong Public Health Clinical Center, Shandong University, Jinan, China. · Shandong Public Health Clinical Center, Shandong University, Jinan, China. gaohongwei202210@163.com.
Key points
From the paper's conclusion- Compared with freehand localization of the rotation axis, guide-assisted localization reduced pin insertion time, fluoroscopic exposures, and pin adjustments. Furthermore, the guide group demonstrated non-inferiority in surgical outcomes compared to the freehand group.
Abstract
PURPOSE: This study evaluated the effect of 3D-printed guides on rotation-axis localization for hinged external fixation in terrible triad (TT) injury of the elbow. METHODS: We enrolled 55 patients with TT injuries treated with a hinged external fixator between January 2017 and January 2025, divided into a guide group (n = 29) and a freehand group (n = 26) according to the method of rotation-axis localization, with follow-up at six weeks and one year postoperatively. Pin insertion time, number of fluoroscopic exposures, elbow range of motion, functional elbow rate, Mayo Elbow Performance Score (MEPS), type and incidence of complications, and number and causes of reoperations were compared between groups. RESULTS: Compared with the freehand group, the guide group had a shorter mean pin insertion time (300.93 ± 21.97 s vs. 1392.5 ± 218.16 s) and fewer fluoroscopic exposures (2.31 ± 0.54 vs. 17.50 ± 2.93; both P < 0.05). At the first follow-up, mean flexion-extension arc (124.21° ± 24.99° vs. 114.69° ± 30.10°), rotation arc (154.48° ± 30.35° vs. 141.85° ± 34.26°), MEPS (95.34 ± 9.81 vs. 91.35 ± 12.85), functional elbow rate (86% vs. 77%), and complication rate (24% vs. 42%) did not differ significantly between groups (P > 0.05). At the final follow-up, flexion-extension arc (134.36° ± 18.21° vs. 125.75° ± 26.44°), rotation arc (165.71° ± 20.34° vs. 157.04° ± 26.84°), MEPS (97.86 ± 7.26 vs. 95.21 ± 11.28), functional elbow rate (93% vs. 79%), and complication rate (11% vs. 21%) remained similar, without significant differences (P > 0.05). During follow-up, one patient in the guide group required reoperation for heterotopic ossification, whereas three patients in the freehand group required reoperation for heterotopic ossification or fixator loosening. CONCLUSION: Compared with freehand localization of the rotation axis, guide-assisted localization reduced pin insertion time, fluoroscopic exposures, and pin adjustments. Furthermore, the guide group demonstrated non-inferiority in surgical outcomes compared to the freehand group.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Three-Dimensional Fracture Mapping of the Terrible Triad of the Elbow: Morphological Characteristics and Clinical Implications.Orthopaedic surgery · 2026
- Association of Coronoid Height Loss with Functional Outcomes in Terrible Triad Injuries Treated Using a Selective Fixation Algorithm.Journal of clinical medicine · 2026
- Combined Management of Meniscus Root Tear and High Tibial Osteotomy: A Surgical Strategy Using 3-Dimensional Printing.Arthroscopy techniques · 2026
- Retrosigmoid craniotomy surgical guide: The way forward for precise exposure of the transverse-sigmoid sinuses.Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia · 2026
- Intraoperative 3D Tomosynthesis of the Elbow in a Simulated Prone-Position Setup: A Cadaveric Study.Diagnostics (Basel, Switzerland) · 2026
- The effects of coronoid fracture fixation on functional outcomes and complication rates following terrible triad injuries of the elbow.Clinics in shoulder and elbow · 2026