Abdominal radiology (New York)

Drawing the line: tumour contact length in the VI-RADS grey zone.

Divyansh Gupta, Parul Gupta, Alok Verma, Naman Gupta, Nauratmal Kumawat, Anu Bhandari

Department of Radiodiagnosis, SMS Medical College, Jaipur, India. drdivyanshrad@gmail.com. · Department of Radiodiagnosis, SMS Medical College, Jaipur, India.

Observational · n=207

Key points

From the paper's conclusion
  • Within VI-RADS 2-3, a pre-specified 30 mm contact-length threshold improved specificity without a significant difference in sensitivity and was reproducible. Contact length complements the VI-RADS category and requires prospective multicentre validation.

Abstract

PURPOSE: To evaluate whether tumour contact length improves discrimination of muscle-invasive bladder cancer within Vesical Imaging-Reporting and Data System (VI-RADS) categories 2 and 3 on 3.0 T multiparametric MRI. METHODS: This prospective single-centre study included 207 consecutive adults with a bladder mass who underwent 3.0 T multiparametric MRI before transurethral resection between February 2024 and January 2026. Two radiologists, blinded to histopathology, independently assigned VI-RADS categories and measured contact length. Histopathology of the resection specimen, or of re-resection when detrusor muscle was absent, was the reference standard. The primary analysis compared contact length ≥ 30 mm with VI-RADS 3 versus 2 within the VI-RADS 2-3 subgroup using McNemar's exact test. RESULTS: Ninety-two patients (44.4%) had muscle-invasive disease. Within the VI-RADS 2-3 subgroup (n = 101; 24 muscle-invasive), contact length ≥ 30 mm yielded a sensitivity of 87.5% (95% CI 67.6-97.3) and a specificity of 76.6% (65.6-85.5), compared with 79.2% and 62.3% for VI-RADS 3 versus 2 (McNemar p = 0.69 and p = 0.043, respectively). Muscle invasion was present in 10.0% of VI-RADS 3 lesions below 30 mm and 60.7% at or above it; for VI-RADS 2 lesions, the proportions were 2.4% and 36.4%. Requiring both criteria increased specificity to 85.7% but missed 7 of 24 muscle-invasive tumours. Inter-reader agreement for contact length was excellent (intraclass correlation coefficient 0.906). CONCLUSION: Within VI-RADS 2-3, a pre-specified 30 mm contact-length threshold improved specificity without a significant difference in sensitivity and was reproducible. Contact length complements the VI-RADS category and requires prospective multicentre validation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers