Augmented and virtual reality for preprocedural planning and intraprocedural guidance in transplant hepatic artery stenting.
Andrew C Gordon, Saad Abu Zahra, Amir A Borhani, Zach Dietch, Daniel Borja-Cacho, Scott Resnick, Robert J Lewandowski
Department of Radiology, Northwestern Medicine, Chicago, USA. andrew-gordon@fsm.northwestern.edu. · Department of Radiology, Northwestern Medicine, Chicago, USA.
Key points
From the paper's conclusion- AR/VR planning for transplant HA stenting is feasible, influencing procedural strategy in 75% of cases with maximum operator ratings for visualization, confidence, and workflow integration. Intraprocedural AR during transradial access was feasible.
Abstract
PURPOSE: Hepatic artery stenosis is a recognized vascular complication after orthotopic liver transplantation, and endovascular treatment is technically demanding because of variable post-surgical anatomy. Augmented and virtual reality (AR/VR) allows immersive review of patient-specific three-dimensional imaging, but its clinical application to transplant hepatic artery interventions remains poorly described. This study evaluated the feasibility, usability, and perceived impact of AR/VR for preprocedural planning and intraprocedural guidance in transplant hepatic artery (HA) stenting. METHODS: This IRB-approved single-center pilot study included eight consecutive patients undergoing transplant HA stenting from January 2025 to May 2026. Preprocedural planning was performed using an AR/VR headset and spatial computing software. In the final three cases, AR was used intraprocedurally to display live fluoroscopy during the procedure. Postprocedure surveys assessed workflow integration, anatomic visualization, confidence, usability, and comfort using 5-point Likert scales. RESULTS: Cases were emergent in 12.5% and elective in 87.5%; 62.5% were high complexity. All cases were technically successful without major complications. Median case, fluoroscopy, and AR/VR planning times were 159.5, 34.8, and 4.5 min, respectively; median air kerma was 678 mGy. AR/VR planning represented 3.6% of case time and was perceived to change the approach in 6/8 cases (75%). Visualization, workflow integration, confidence, and anatomic understanding each received median scores of 5. Headset comfort was lowest-rated. Intraprocedural AR was successful in all 3 cases. CONCLUSION: AR/VR planning for transplant HA stenting is feasible, influencing procedural strategy in 75% of cases with maximum operator ratings for visualization, confidence, and workflow integration. Intraprocedural AR during transradial access was feasible.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of augmented reality for interstitial brachytherapy optimisation: a prospective phantom-based study protocol and preliminary results.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2026
- A Visual Support System for Stent-Assisted Treatment of Cerebral Aneurysms Using 3D Imaging and Augmented Reality.Neuroinformatics · 2026
- Feasibility and Usability of Head-Mounted Display Augmented Reality During Routine Radiological Interventions: The Prospective AZURION-AR Study.Cardiovascular and interventional radiology · 2026
- In Situ vs. Monitor-Based: Evaluating Augmented Reality for Ultrasound-Guided Peripheral Venous Catheter Insertion.IEEE transactions on visualization and computer graphics · 2026
- Clinical accuracy and efficiency of augmented reality head-mounted displays in cranial neurosurgery: a systematic reviewThe Egyptian Journal of Neurology, Psychiatry and Neurosurgery · 2026
- Interventional Radiology Management After Early Hepatic Artery Thrombosis Following Pediatric Liver Transplantation.Pediatric transplantation · 2026