Is ultrasonic speed of sound estimation for liver fat quantification affected by measurement depth?
Halit Nahit Şendur, Mehmet Ali Yeşilçimen, Mahi Nur Cerit, Atiye Cenay Karabörk Kılıç, Suna Özhan Oktar
Department of Radiology, Gazi University Faculty of Medicine, Ankara, Turkey. hsendur@gazi.edu.tr. · Department of Radiology, Gazi University Faculty of Medicine, Ankara, Turkey.
Key points
From the paper's conclusion- Our results revealed that ultrasonic SS measurements are affected by the measurement depth in patients with high BMI and high SLC. These findings may be valuable for technical standardization of SS technique.
Abstract
PURPOSE: Ultrasonic speed of sound (SS) estimation is one of the techniques that can be used to assess hepatic fat content. Current literature lacks of information for ultrasonic SS estimation technique in terms of depth dependence. We aimed to evaluate the impact of measurement depth on SS measurements. METHODS: A total of 90 patients who diagnosed with metabolic dysfunction-associated steatotic liver disease (MASLD) were included in the study. Upper edge of the region of interests (ROI) were positioned at 4 cm and 6 cm deep from the skin. Five measurements were obtained for both depths and the median values were noted for the analysis. Paired-t test was used to compare the measurements. RESULTS: The means of the SS measurements for 4 cm and 6 cm depths were 1514 ± 13.5 m/s and 1512.2 ± 15.1 m/s, respectively. There was a significant difference between the SS measurements obtained at 4 cm and 6 cm depths (P = 0.018). Subgroup analyses for BMI (< 30 kg/m2 vs. ≥ 30 kg/m2) and skin to liver capsule (SLC) distance (< 25 mm vs. ≥ 25 mm) revealed that there were significant differences in SS measurements between 4 cm and 6 cm depths in patients with high BMI (P = 0.047) and high SLC (P = 0.044), while there were no significant differences detected in patients with low BMI (P = 0.198) and low SLC (P = 0.140). CONCLUSION: Our results revealed that ultrasonic SS measurements are affected by the measurement depth in patients with high BMI and high SLC. These findings may be valuable for technical standardization of SS technique.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of acquisition geometry on ultrasound-derived fat fraction measurements: implications for standardized acquisition and measurement interchangeability.Quantitative imaging in medicine and surgery · 2026
- Ultrasound quantification of liver fat in MASLD.European radiology · 2026
- Discovery of ultrasound-derived fat fraction as a non-invasive tool for MASLD diagnosisEuropean journal of medical research · 2025
- Ultrasound-derived visceral adipose tissue as a reliable marker of hepato-metabolic risk in patients with MASLDDigestive and Liver Disease · 2025
- Associations of Ultrasound-Derived Fat Fraction and MRI PDFF Measurements: A Prospective Study in Pediatric Patients With Suspected MASLDAmerican Journal of Roentgenology · 2026
- Advances in quantitative ultrasound for metabolic dysfunction-associated steatotic liver disease diagnosisFrontiers in Physiology · 2026