  • 18F-FDG PET/CT shows promise as an important tool for the early detection and monitoring of immune-related toxicities. However, the utility of PET-irAEs as imaging biomarkers for predicting treatment response and prognosis requires further validation in large-scale prospective studies.

Abstract

PURPOSE: Immune checkpoint inhibitors (ICIs) can induce immune-related adverse events (irAEs), including subclinical inflammatory toxicities detectable by 18F-FDG PET/CT. This systematic review aimed to synthesize current evidence on the organ distribution, diagnostic utility, and prognostic significance of PET-detected irAEs (PET-irAEs) in patients with cancer. METHODS: A systematic search of PubMed, Web of Science and Embase was conducted through September 2026. Studies reporting on PET-detected irAEs and clinical outcomes in human participants treated with ICIs were included. Data were summarized via narrative synthesis. No formal meta-analysis was performed; organ-site events were aggregated descriptively by cancer type. RESULTS: PET-irAEs displayed cancer-specific organ profiles: bladder cancer showed thyroid (34%) and gastrointestinal (28.3%) enrichment; non-small-cell lung carcinoma (NSCLC) was characterized by gastrointestinal (50%) and pulmonary (19.5%) involvement and melanoma exhibited a heterogeneous multisystem distribution. Evidence regarding the predictive and prognostic significance of PET-irAEs remains inconsistent. Although several studies have demonstrated associations between PET-irAEs and favorable treatment responses or survival outcomes, others have reported no statistically significant relationships. Interpretation of the available evidence is limited by small sample sizes, the lack of adjusted analyses, and susceptibility to selection bias, residual confounding, and time-dependent bias. CONCLUSION: 18F-FDG PET/CT shows promise as an important tool for the early detection and monitoring of immune-related toxicities. However, the utility of PET-irAEs as imaging biomarkers for predicting treatment response and prognosis requires further validation in large-scale prospective studies.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers