Stage-dependent performance and molecular subtype-specific relapse patterns on same-session [18F]FDG PET/contrast-enhanced CT in breast cancer.
Agostino Chiaravalloti, Shyqyri Samarxhiu, Ilaria Portarena, Valeria Flaminio, Nicola D'Ascenzo, Orazio Schillaci, Gianluca Vanni
Department of Biomedicine and Prevention, University of Rome Tor Vergata, Viale Montpellier 1, Rome, 00133, Italy. agostino.chiaravalloti@uniroma2.it. · Department of Biomedicine and Prevention, University of Rome Tor Vergata, Viale Montpellier 1, Rome, 00133, Italy.
Key points
From the paper's conclusion- Same-session [18F]FDG PET/ceCT showed greatest baseline utility in higher-risk breast cancer and was useful for longitudinal characterization of relapse phenotype and metastatic evolution.
Abstract
PURPOSE: To evaluate stage-dependent performance of same-session [18F]FDG PET/contrast-enhanced CT (PET/ceCT) for initial breast cancer staging and PET/ceCT-detected relapse patterns during follow-up. METHODS: This retrospective single-centre study included a primary staging cohort with one index PET/ceCT per patient and a longitudinal cohort of follow-up/restaging examinations. PET/ceCT-derived endpoints were assessed against clinically adjudicated reference standards established through multidisciplinary team review, pathology when available and follow-up imaging. SUVmax and ceCT lesion diameter were analysed as exploratory biomarkers. RESULTS: The staging cohort included 116 patients. Baseline stage was evaluable in 106 patients: 65 had cN-positive disease, 9 had cT3-4 cN0 disease and 32 had cT1-2 cN0 disease. Overall nodal staging performance showed sensitivity 64.8%, specificity 88.9%, PPV 92.0%, NPV 56.1% and accuracy 72.9%. In cT3-4 and/or cN-positive disease, PET-positive nodal findings had a PPV of 100%. Baseline M-stage assessment was limited by the low number of clinically confirmed M1 cases. SUVmax correlated with Ki-67 (rho = 0.322, p = 0.003, q = 0.022). The longitudinal cohort included 176 patients and 429 examinations. In 311 adjudicated examinations, restaging performance for disease progression showed sensitivity 100%, specificity 93.5%, PPV 97.3%, NPV 100% and accuracy 98.1%. First confirmed relapse was multiorgan/multisystem in 48/82 patients and visceral-only in 15/82; visceral conversion occurred in 5/16 patients with initial bone-only or nodal/locoregional relapse. CONCLUSION: Same-session [18F]FDG PET/ceCT showed greatest baseline utility in higher-risk breast cancer and was useful for longitudinal characterization of relapse phenotype and metastatic evolution.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Predictive value of preoperative [18F]FDG PET/CT imaging parameters for postoperative recurrence and metastasis in breast cancer patients.Frontiers in oncology · 2026
- Association of PET/CT-Derived Metabolic Parameters with Pathological Complete Response After Neoadjuvant Systemic Therapy in Breast Cancer: An Analysis Across Molecular Subtypes.Diagnostics (Basel, Switzerland) · 2026
- Prognostic role of 18FDG-PET/CT based biomarker, tumor grading and immunohistochemical markers in breast cancer survivalScientific Reports · 2026
- Site-Specific Patterns of Distant Relapse on ^18F-FDG PET/Contrast-Enhanced CT According to Molecular Subtype in Breast Cancer: A Retrospective Cohort Study.Nuclear medicine and molecular imaging · 2026
- Comparison of 68ga fapi pet/ct and 18f-fdg pet/ct in primary staging of breast cancer.European journal of radiology · 2026
- Limited clinical value of routine PET/CT in early-stage breast cancer: a multicenter retrospective study.Breast cancer (Tokyo, Japan) · 2026