Diagnostic performance and reproducibility of standardized two-plane ultrasound cine clips for supraspinatus tendon pathology.

Sono Khan, Juvel Lee, Zaid Jibri, Fabricio de Oliveira Cyrineu, Marcos Loreto Sampaio

Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada. · Department of Radiology, University of British Columbia, Vancouver General Hospital, Vancouver, BC, Canada.

Observational

Key points

From the paper's conclusion
  • Standardized two-plane cine clips demonstrate high diagnostic performance and inter-observer reliability for full-thickness supraspinatus tears. For complete tears, inter-observer agreement was moderate and sensitivity was imprecise. Given limited sensitivity for partial-thickness tears and low specificity for tendinopathy, cine clips alone are insufficient for these pathologies and should complement rather than replace complete real-time shoulder ultrasound examinations.

Abstract

OBJECTIVE: To determine the diagnostic performance and reader reproducibility of standardized two-plane cine clips for supraspinatus tendon pathology, using the complete radiologist-supervised shoulder ultrasound examination as the clinical reference standard. MATERIALS AND METHODS: This prospective single-centre study screened 140 consecutive shoulder ultrasound examinations. Standardized longitudinal and transverse supraspinatus cine clips were independently reviewed by two fellowship-trained musculoskeletal radiologists blinded to the clinical report. Reader 1 read all included examinations (24 twice); Reader 2 read 51. Diagnostic performance (exact 95% confidence intervals) was calculated against the same-day clinical ultrasound report, and reliability with Cohen's κ. Reporting radiologists could access the standardized clips. RESULTS: Of 140 examinations, 114 were analyzed (mean age 57 years; 56 women). Reader 1 showed high performance for full-thickness tears (sensitivity 87% [95% confidence interval 69-96%], specificity 98% [92-100%]) and complete tears (sensitivity 73% [39-94%], specificity 97% [92-99%]). Calcific tendinopathy yielded sensitivity/specificity of 79%/85%; partial-thickness tears, 57%/87%; and tendinopathy, 92%/28%. Reader 2 sensitivity was 92% [64-100%] for full-thickness and 18% [2-52%] for partial-thickness tears. Intra-observer κ ranged from 0.17 (tendinopathy) to 0.89 (full-thickness tears). Inter-observer κ was 0.95 for full-thickness, 0.56 for complete and 0.21 for partial-thickness tears. CONCLUSION: Standardized two-plane cine clips demonstrate high diagnostic performance and inter-observer reliability for full-thickness supraspinatus tears. For complete tears, inter-observer agreement was moderate and sensitivity was imprecise. Given limited sensitivity for partial-thickness tears and low specificity for tendinopathy, cine clips alone are insufficient for these pathologies and should complement rather than replace complete real-time shoulder ultrasound examinations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers