Zero-shot segmentation and tumor diameter measurement of soft tissue sarcomas on MRI using a multimodal large language model.
Haruto Sugawara, Shimpei Kato, Akiyo Takada
Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, 501 Smyth Road, Ottawa, Ontario, K1H 8L6, Canada. capy.sugawara@gmail.com. · Department of Radiology, Institute of Medical Science, The University of Tokyo, Tokyo, Japan.
Key points
From the paper's conclusion- Gemini 3.0 achieved high accuracy in zero-shot segmentation of STS on MRI. Deriving quantitative measurements from automated segmentation proved significantly more reliable than direct size estimation by the large language model.
Abstract
OBJECTIVES: To evaluate the zero-shot capabilities of a multimodal deep learning model (Gemini 3.0) in segmenting Soft Tissue Sarcomas (STS) on MRI and to compare the accuracy of tumor diameter measurements derived from automated segmentation versus direct model estimation. METHODS: This retrospective study utilized a public dataset (The Cancer Imaging Archive) consisting of 51 patients (mean age, 54.8 ± 17.0 years; 24 men, 27 women) with histologically confirmed STS. Gemini 3.0 performed zero-shot lesion segmentation and direct diameter estimation on a fat-suppressed T2-weighted or STIR image. Segmentation accuracy was evaluated using the Dice similarity coefficient (DSC) against manual segmentation by a board-certified radiologist. Tumor diameters derived from Gemini segmentation masks and direct estimates were compared with manual measurements using intraclass correlation coefficients (ICC) and Bland-Altman analysis. Bootstrap analysis was performed to compare the performance of the two automated measurement methods. RESULTS: Gemini generated segmentation masks with a mean DSC of 0.935 ± 0.082, comparable to inter-radiologist agreement (0.949 ± 0.037) and showing high reproducibility (DSC, 0.981 ± 0.038). For tumor size assessment, the segmentation-derived measurement yielded an ICC of 0.976, significantly higher than the direct estimation ICC of 0.922 (p = 0.027). Bland-Altman analysis revealed a smaller mean bias for the segmentation-based approach (-0.5 mm) compared with direct estimation (-5.0 mm). CONCLUSIONS: Gemini 3.0 achieved high accuracy in zero-shot segmentation of STS on MRI. Deriving quantitative measurements from automated segmentation proved significantly more reliable than direct size estimation by the large language model.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Integrating nnU ‐Net Segmentation and Clinical–Radiomics for Multicenter MRI ‐Based Assessment of Soft Tissue Sarcoma Grade and Ki‐67 ExpressionJournal of Magnetic Resonance Imaging · 2026
- Beyond proof-of-concept: Validating robust automated diffuse lower-grade glioma segmentation for clinical applications in longitudinal follow-upNeuro-Oncology Advances · 2025
- Volumetric Latent Diffusion for Brain Tumour Segmentation with Missing ModalitiesarXiv · 2026
- Performance of deep learning-based segmentation of soft tissue sarcoma by MRI sequence, tumor type and locationSkeletal Radiology · 2026
- MS ‐ FSSM : A Multi‐Scale Frequency‐Sensitive State Space Model for Brain Tumor Segmentation in Multi‐Modal MRIIEEJ Transactions on Electrical and Electronic Engineering · 2026
- Deep Learning-Based Multiple Sclerosis Lesion Segmentation at 7 Tesla: Comparison of Single- and Multi-Contrast MRI Inputs.Journal of imaging · 2026