Bubble-enhanced cold plasma improves microbial inactivation in water under scalable conditions.
José Gonçalves, João Pequeno, Jure Žigon, Tom Koritnik, Filipe Ferreira da Silva, Davor Kržišnik, Marija Trkov, Israel Diaz,
MARE - Marine and Environmental Sciences Centre, ARNET - Aquatic Research Network Associate Laboratory, NOVA School of Science and Technology, NOVA University Lisbon, Caparica, Portugal. jose.goncalves@fct.unl.pt. · MARE - Marine and Environmental Sciences Centre, ARNET - Aquatic Research Network Associate Laboratory, NOVA School of Science and Technology, NOVA University Lisbon, Caparica, Portugal.
Key points
From the paper's conclusion- These results position bubble‑assisted CAP as a promising environmental biotechnology and bioprocess platform for water disinfection and emphasise the central role of reactor and contactor design in determining microbial efficacy and energy demand.
Abstract
Cold atmospheric plasma (CAP) is emerging as an environmentally friendly disinfection technology, but most plasma-liquid systems remain confined to millilitre‑scale volumes, limiting their applicability as bioprocesses for water treatment. Here, we designed and evaluated a bubble‑enhanced dielectric barrier discharge reactor, the Spiral Plasma Aeration Reactor Column (SPARC), as an environmental technology approach for litre‑scale inactivation of model bacteria in water. Direct CAP exposure achieved rapid, near‑complete inactivation of Escherichia coli and Bacillus subtilis in 200 µL, but performance decreased sharply at 100 mL, confirming strong volume dependence under surface‑limited plasma-liquid contact. Coupling CAP with gas bubbling (2 L·min-1) in SPARC markedly enhanced inactivation at 250-500 mL, achieving approximately 2-3 log reductions (≥ 99-99.9%) for E. coli and B. subtilis within 60 min, whereas non-aerated CAP remained below ≈0.8-log (≤ 60%) reduction under identical conditions. At 1 L under high initial loads (~ 106-107 CFU·100 mL-1), bubble-assisted CAP yielded ~ 4-log inactivation of E. coli and 3-3.5-log reduction of B. subtilis, including continued post-treatment inactivation consistent with plasma-activated water effects. In a protein‑rich organic matrix, early‑stage inactivation was attenuated, but SPARC still achieved ≈2-3‑log reductions, indicating robust yet matrix‑sensitive performance under wastewater‑like conditions. At fixed electrical input (34.5 W), specific energy consumption ranged from 60 kWh·m-3 (250 mL, 30 min, > 99% E. coli inactivation) to 30 kWh·m-3 (1 L, 60 min, ≈4‑log E. coli inactivation), corresponding to ≈7.5 kWh·log₁₀-1·m-3. These results position bubble‑assisted CAP as a promising environmental biotechnology and bioprocess platform for water disinfection and emphasise the central role of reactor and contactor design in determining microbial efficacy and energy demand. KEY POINTS: • Direct CAP exposure in microlitre-scale water (200 µL) produces rapid ≥ 3-log₁₀ (> 99.9%) inactivation of E. coli and B. subtilis, but performance deteriorates at 100 mL, confirming strong volume dependence under surface-limited plasma-liquid contact. • The bubble-enhanced DBD reactor SPARC, operated at 250-500 mL, achieves ≈2-3-log₁₀ (≥ 99-99.9%) bacterial reductions within 60 min, whereas non-aerated CAP under identical electrical conditions generally remains below ≈0.8-log₁₀ (≤ 60%) reduction. • At 1 L, bubble-assisted SPARC attains ~ 4-log₁₀ (E. coli) and 3-3.5-log₁₀ (B. subtilis) inactivation under high initial loads, with specific energy consumption between 30 and 60 kWh·m-3 (≈7.5 kWh·log₁₀-1·m-3) for the laboratory prototype.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Low-flow argon cold atmospheric plasma jet for E. coli inactivation and PAW fingerprintingCurrent Directions in Biomedical Engineering · 2026
- High‐Efficiency Bacterial Inactivation of a Plasma Water Treatment System Using Flexible Coplanar Dielectric Barrier DischargePlasma Processes and Polymers · 2026
- Antimicrobial efficacy and cytotoxic assessment of plasma-activated water generated by a dielectric barrier discharge microbubble systemFrontiers in Microbiology · 2026
- Surface scan cold plasma technology for effective inhibition of Staphylococcus epidermidis and Escherichia coliScientific Reports · 2026
- Insight into discharge mode transition in spatially confined pulsed bubbles-plasma systemApplied Physics Letters · 2025
- Influence of Plasma Reactor Configuration on the Physicochemical Properties, Stability, and Biological Activity of Plasma-Activated WaterProcesses · 2026