Musculoskeletal ultrasonography of lower extremity entheses in children and adolescents - a pilot study of normal B-mode and Doppler characteristics.
Sandra Hansmann, Johannes Roth
Department of Neuropediatrics, General Pediatrics, Diabetology, Endocrinology and Social Pediatrics, University Children's Hospital Tübingen, Tübingen, Hoppe-Seyler-Str. 1, 72076 Tübingen, Germany. sandra.hansmann@klinikum.uni-tuebingen.de. · Childrens's Hospital of Central Switzerland, University of Lucerne, Lucerne, Switzerland.
Key points
From the paper's conclusion- Entheseal thickness correlates with age, but sex differences are minimal. Mild signals are common at the sartorius, quadriceps, and Achilles entheses with normal B-mode findings. Pathologic Doppler may require accompanying B-mode abnormalities. These data broaden the base for ultrasonography of pediatric entheses and facilitate differentiation of pathology from normal findings.
Abstract
BACKGROUND: Musculoskeletal ultrasonography is an important imaging modality in children. Features of arthritis are well defined and age-related normative data exist. Data on entheses are limited with no consensus on definition of pathology. OBJECTIVES: The aim of this pilot study was to evaluate entheseal thickness, echotexture, and presence of vascularity in healthy children and adolescents as a prerequisite for distinction from pathology. MATERIALS AND METHODS: Children and adolescents without musculoskeletal conditions underwent standardized B-mode and power Doppler ultrasonography of the dominant hip, knee, and ankle entheses. Entheseal thickness, echotexture, and vascularity were assessed, alongside demographic, puberty, and physical activity data. Statistical analysis included intraclass correlation coefficients, single regression, and t-tests. RESULTS: Seventy-nine healthy participants (mean age 10.5 years; 48% female) were included. All 782 evaluated entheses showed normal B-mode echotexture. Inter- and intraobserver reliability was high to excellent, with intraclass correlation coefficient values ranging from 0.84-0.99 and 0.91-0.99, respectively. Entheseal thickness correlated significantly with age (r = 0.65-0.90), lacking sex-specific differences at most sites. Minor power Doppler activity was detected in 1-44% of entheses within 2 mm of the insertion, increasing to 2-68% within 5 mm. Doppler signals were most frequent at proximal sartorius and knee entheses. CONCLUSION: Entheseal thickness correlates with age, but sex differences are minimal. Mild signals are common at the sartorius, quadriceps, and Achilles entheses with normal B-mode findings. Pathologic Doppler may require accompanying B-mode abnormalities. These data broaden the base for ultrasonography of pediatric entheses and facilitate differentiation of pathology from normal findings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reliability of Ultrasound Measurements in the Assessment of Femoral Trochlear Morphology in Healthy AdolescentsDiagnostics · 2026
- Gestational age-specific reference percentiles for sonographic anterior thigh muscle thickness in newborns: A prospective observational study.Early human development · 2026
- Discordance among skeletal maturity indicators: sources, interpretation, and clinical implications.Frontiers in pediatrics · 2026
- Association between patellar tendon-related pain and morphological abnormalities of the patellar tendon visualized using ultrasound imaging in middle school athletes.PloS one · 2026
- Defining the musculoskeletal ultrasound phenotype of ochronotic arthropathy: a systematic study of 34 patients with alkaptonuria.Clinical rheumatology · 2026
- Ultrasound assessment of patellar enthesopathy in patients with Ehlers-Danlos syndrome with and without concomitant axial spondyloarthropathy.Journal of ultrasonography · 2025