Department of Clinical Epidemiology and Biostatistics, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea. · Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea. ghw68@hanmail.net.

Key points

From the paper's conclusion
  • The systematic differences and incomplete agreement between CT-based and echocardiography-based Z-scores indicate that echocardiographic reference equations should not be applied interchangeably to CT measurements.

Abstract

Pediatric cardiac computed tomography (CT) is increasingly used to identify and monitor coronary artery lesions caused by Kawasaki disease. This study was aimed to develop a CT-based normative coronary artery Z-score method derived from normal pediatric coronary arteries and to compare the Z-scores between the CT- and echocardiography-based methods. A total of 298 children (age range, 1 month - 18 years) with no or trivial cardiovascular disease who underwent ECG-synchronized dual-source cardiac CT were included. Coronary artery diameters were measured in six segments: the left main, proximal and distal left anterior descending, left circumflex, and proximal and distal right coronary arteries. Using the measured coronary artery diameter and body surface area for each segment, Z-scores for normal pediatric coronary arteries were estimated using the lambda-mu-sigma method. The Z-scores using CT-based method were correlated and compared with those using echocardiography-based methods. The CT-based coronary artery Z-score method was developed using the square root model for all six segments, with corresponding Z-score curves generated. The CT- and echocardiography-based methods demonstrated high correlations (R = 0.90 to 0.99; p < 0.001). Echocardiography-based methods frequently produced higher or lower Z-scores, compared with the CT-based values. Bland-Altman plots illustrated the estimated bias from - 0.6 to 0.1 and the 95% limits of agreement ranging from - 0.2 ~ 0.5 to -1.0 ~ 0.8. The CT-based method demonstrated moderate-to-good agreements with echocardiography-based methods (k = 0.427 and 0.640, P < 0.001). This study provides CT-specific coronary artery Z-score models for proximal and distal coronary segments across a broad pediatric age range. The systematic differences and incomplete agreement between CT-based and echocardiography-based Z-scores indicate that echocardiographic reference equations should not be applied interchangeably to CT measurements.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers