Noninvasive Insights: Magnetic Resonance Elastography and Ultrasound Liver Elastography for the Assessment of Liver Fibrosis in Fontan-Associated Liver Disease: A Comparative Study with Histology.
Saviga Sethasathien, Rekwan Sittiwangkul, Apinya Leerapun, Sarawut Kongkarnka, Nakarin Inmutto, Phanu Prasankittirach, Pakpoom Wongyikul, Phichayut Phinyo,
Division of Pediatric Cardiology, Department of Pediatrics, Faculty of Medicine, Chiang Mai University, Chiang Mai, 50200, Thailand. · Division of Gastroenterology Diseases, Department of Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.
Key points
From the paper's conclusion- This study included 34 Fontan patients with a mean age of 20.2 ± 6 years, 23 (67.6%) had fibrosis ≥2B.
Abstract
The diagnostic performance of ultrasound (U/S) elastography and magnetic resonance elastography (MRE) of liver relative to histological assessment in Fontan patients remains uncertain. This study sought to evaluate the diagnostic accuracy and agreement of MRE and U/S elastography compared with histological congestive hepatic fibrosis score (CHFS) staging. We conducted a cross-sectional study in Fontan patients. Patients were categorized into non-significant fibrosis (≤ 2 A) and advanced fibrosis (≥ 2B) groups according to the CHFS scoring system. This study included 34 Fontan patients with a mean age of 20.2 ± 6 years, 23 (67.6%) had fibrosis ≥2B. The majority of whom had undergone an extracardiac conduit Fontan procedure. Hemodynamic parameters were similar between groups. MRE values were significantly higher in the fibrosis group (5.0 ± 0.9 vs. 4.1 ± 1.1 kPa, p = 0.018), whereas U/S elastography values did not differ significantly (p = 0.568). MRE demonstrated fair agreement with biopsy (quadratic-weighted κ = 0.468), while ultrasound showed no meaningful agreement (κ=-0.057). MRE demonstrated acceptable discriminative performance (AUC 0.77; 95% CI: 0.57-0.97), whereas ultrasound elastography showed poor discrimination (AUC 0.44; 95% CI: 0.21-0.66), both estimated from the continuous liver stiffness value in kilopascals; the two areas under the curve differed by 0.33 (95% CI: 0.06-0.60; DeLong p = 0.018). MRE demonstrates better agreement with histology and higher diagnostic performance compared with U/S elastography in Fontan patients. However, its discriminatory capacity, as reflected by AUC, remains lower than that reported in other chronic liver diseases. These findings highlight the unique pathophysiological substrate of Fontan-associated liver disease and underscore the need to establish disease-specific MRE cut-off values for each staging system to achieve more accurate fibrosis stratification and meaningful clinical application.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comprehensive Evaluation of Fontan-Associated Liver Disease: The Role of Magnetic Resonance Imaging.Diagnostics (Basel, Switzerland) · 2026
- Evaluation of magnetic resonance elastography performance in the assessment of clinically significant liver fibrosis in pediatric metabolic dysfunction-associated steatotic liver disease.Journal of pediatric gastroenterology and nutrition · 2026
- Diagnostic Performance of Magnetic Resonance Elastography Versus Vibration‐Controlled Transient Elastography for Liver Fibrosis Staging in Steatotic Liver DiseaseNMR in Biomedicine · 2026
- Non-Invasive Imaging Assessment of Liver Fibrosis.Journal of medical imaging and radiation oncology · 2026
- Chronic Liver Disease: Assessing Inflammation and Fibrosis Using Three‐Dimensional MR Elastography With Same‐Day Biopsy in a Prospective CohortJournal of Magnetic Resonance Imaging · 2026
- Superiority of magnetic resonance elastography and proton density fat fraction: an umbrella meta-analysis of non-invasive imaging for hepatic steatosis and fibrosis in metabolic dysfunction-associated steatotic liver disease and chronic hepatitis B.Quantitative imaging in medicine and surgery · 2026