Using a Consensus Reference Standard to Achieve High Reliability in Grading Aortic Stenosis in an Academic Pediatric Echo Lab.
Bethan A Lemley, Peter Koenig, Angira Patel, Shivani Patel, Joshua Robinson, Pei-Ni Jone
Division of Cardiology, Department of Pediatrics, Feinberg School of Medicine, Lurie Children's Hospital, Northwestern University, 225 E Chicago Ave, PO Box 21, Chicago, IL, 60611, USA. blemley@luriechildrens.org. · Division of Cardiology, Department of Pediatrics, Feinberg School of Medicine, Lurie Children's Hospital, Northwestern University, 225 E Chicago Ave, PO Box 21, Chicago, IL, 60611, USA.
Key points
From the paper's conclusion- Using a consensus reference standard for grading AS may result in high interrater reliability in pediatric echo labs.
Abstract
Accuracy and reliability are important in grading aortic stenosis (AS) by echocardiogram. There are no pediatric-specific consensus guidelines for grading AS by echo. Our objective was to adopt a consensus reference standard for AS and evaluate resulting interrater reliability in a pediatric echo laboratory. A reference standard for grading AS was derived from published adult guidelines. Measurements for mean gradient and aortic valve area as determined by the continuity equation were included. Comparisons were made between AS grades on 20 historic echo reports and AS grades using the new reference standard. Additionally, 6 readers used the reference standard to grade 10 studies prospectively and interrater reliability was evaluated for measurements required for grading AS and overall AS grade. Twenty echo studies were included (median subject age 7 IQR 4-16 years, median weight 32.2 IQR 13.8-44.8 kg). AS grade on historic echo reports and AS grade using new reference standard were in agreement 85% of the time. In the prospective portion of the study there was substantial agreement between raters on overall AS grade (Fleiss' kappa statistic 0.76 95% CI 0.54-0.98). There was excellent interrater reliability in measures of peak gradient (ICC 0.92, 95% CI 0.82-0.98), mean gradient (ICC 0.95, 95% CI 0.88-0.98), left ventricular outflow tract diameter (ICC 0.96, 95% CI 0.92-0.99), and left ventricular outflow tract velocity time integral (ICC 0.94, 95% CI 0.75-0.99). Using a consensus reference standard for grading AS may result in high interrater reliability in pediatric echo labs. Measurements of the mean gradient and measurements needed for the continuity equation for aortic valve area have high interrater reliability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Association of Guideline-Concordant Echocardiographic Surveillance With Mortality and Aortic Valve Replacement in US Adults With Aortic StenosisCirculation Population Health and Outcomes · 2026
- Discordant low-gradient aortic stenosis: a phenotype-first, likelihood-tiered multimodality imaging framework.Frontiers in cardiovascular medicine · 2026
- Methodological Updates in Stress Echocardiography and Multimodality Diagnostic Integration for Discordant Low-Gradient Aortic Stenosis: From True-Severe Adjudication to Risk Stratification.Reviews in cardiovascular medicine · 2026
- Assessment of the Variability of an Echo-Doppler Method for Measurement of Aortic Pulse Wave Velocity.CJC pediatric and congenital heart disease · 2026
- Novel Transvalvular Flow Criteria Reduce Indeterminate Stress Echocardiography and Refine Risk Stratification in Low-Gradient Aortic Stenosis.Circulation. Cardiovascular imaging · 2026
- Revealing hidden severity: three-dimensional transoesophageal echocardiography planimetry in low-flow, low-gradient aortic stenosisEuropean Heart Journal · 2026