  • MRI-derived synthetic [18F]FET PET may enhance glioma grading and HGG-SBM differentiation, providing a PET-like alternative when FET PET is unavailable.

Abstract

BACKGROUND: O-(2-[18F]fluoroethyl)-L-tyrosine positron emission tomography ([18F]FET PET) is clinically useful in neuro-oncology but limited by cost and availability. We assessed the clinical utility of magnetic resonance imaging (MRI)-derived synthetic [18F]FET PET. METHODS: A total of 489 patients with histologically confirmed gliomas or brain metastases were retrospectively analyzed. A deep learning model generated synthetic PET images from multimodal MRI in the overall cohort and subgroups. Synthetic PET was evaluated against reference PET for image similarity by peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM), standardized uptake value ratio (SUVR) analysis by Pearson correlation and Bland-Altman analysis, and blinded reader assessment for glioma grading and high-grade glioma (HGG) versus solitary brain metastasis (SBM) differentiation using receiver operating characteristic analysis with area under the curve (AUC). RESULTS: Synthetic PET showed high similarity to reference PET in the overall, glioma, and metastasis groups (PSNR, 34.7-35.5 dB; SSIM, 0.90-0.96), and SUVR correlations were strong (r = 0.77-0.93, all P < 0.001), with minimal bias and narrow limits of agreement. Compared with MRI alone, MRI with synthetic PET improved glioma grading and HGG-SBM differentiation, increasing AUC from 0.815 to 0.941 and from 0.816 to 0.901 for glioma grading and from 0.731 to 0.871 and from 0.784 to 0.872 for HGG-SBM differentiation across the 2 readers (all P < 0.05). No significant differences were found between MRI with synthetic and reference PET for either task (all P > 0.05). CONCLUSIONS: MRI-derived synthetic [18F]FET PET may enhance glioma grading and HGG-SBM differentiation, providing a PET-like alternative when FET PET is unavailable.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers