Safety and efficacy of endovascular treatment of wide-neck intracranial aneurysms: comparison between stent-assisted coiling and intrasaccular flow disruption with the contour device.
Gregor Peter, Lukas Meyer, Luca Meucci, Vincent Geest, Felix Schlicht, Matthias Bechstein, Bogdana Tokareva, Christian Heitkamp,
Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany. g.peter@uke.de. · Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Key points
From the paper's conclusion- In elective EVT of unruptured wide-neck intracranial aneurysms, stent-assisted coiling was associated with a significantly higher rate of postprocedural DWI lesions compared to the Contour device. Periprocedural complications and retreatment rates were similar between the treatment strategies.
Abstract
PURPOSE: To investigate the association between endovascular treatment strategy and the occurrence of postprocedural DWI lesions and periprocedural complications as well as retreatment rates in patients undergoing elective endovascular treatment (EVT) for unruptured wide-neck intracranial aneurysms. METHODS: This retrospective single-center study includes all consecutive patients who underwent elective EVT with stent-assisted coiling (SAC) or Contour device (CD) of unruptured wide-neck intracranial aneurysms between January 2019 and January 2026. Wide-neck aneurysms were defined as aneurysms with a neck ≥4 mm and/or a dome-to-neck ratio < 2. Postprocedural MRI was assessed for new DWI lesions. Uni- and multivariable regression analysis was performed to identify predictors for the primary outcome variables DWI lesions and periprocedural complications. Secondary outcome variables included procedure time, residual perfusion and retreatment rates. RESULTS: A total of 96 patients (50% SAC, 50% CD) were included. Postprocedural DWI lesions were detected in 60% of patients overall with a significant difference between the two groups (78% SAC vs. 43% CD; p<0.001). Periprocedural complications (SAC 13% vs. CD 13%; p = 1.0) and retreatment rates (SAC 7% vs. CD 6%; p = 0.754) did not differ between the two groups. In a multivariate regression analysis, SAC (aOR 4.15, 95% CI 1.39-12.4, p = 0.011) was an independent predictor of postprocedural DWI lesions. CONCLUSION: In elective EVT of unruptured wide-neck intracranial aneurysms, stent-assisted coiling was associated with a significantly higher rate of postprocedural DWI lesions compared to the Contour device. Periprocedural complications and retreatment rates were similar between the treatment strategies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Role of light transmission aggregometry in predicting diffusion-weighted imaging lesions after stent-assisted coil embolization for intracranial aneurysms: a retrospective propensity score-matched study.Frontiers in neurology · 2026
- Stent-assisted coiling versus simple coiling for ruptured intracranial aneurysms in the acute phase: A single-center retrospective cohort study.Journal of cerebrovascular and endovascular neurosurgery · 2026
- Impact of Woven EndoBridge (WEB) device protrusion on postprocedural diffusion-weighted imaging lesions.Journal of neurointerventional surgery · 2026
- Cumulative intraprocedural complexity and diffusion-weighted imaging lesions after endovascular coil embolization.The neuroradiology journal · 2026
- Efficacy and Safety of Stent-Assisted Coiling Versus Coiling Alone for Ruptured Multilobed Aneurysms: A Multicenter Study.Stroke (Hoboken, N.J.) · 2026
- Stent assisted coiling versus non-stent assisted coiling for unruptured intracranial aneurysms: a systematic review and meta-analysis for clinical and angiographic outcomesEgyptian Journal of Neurosurgery · 2026