Neuroradiology

Comparison of braided versus laser-cut stent placement for ruptured intracranial aneurysms in the acute phase: a propensity score matched study.

Yingxue Luo, Yitong Zhao, Chi Huang, Jiwan Huang, Xueyan Deng, Gege Shang, Xin Feng, Xifeng Li,

The School of Public Health, Southern Medical University, Guangzhou City, 510515, China. · Neurosurgery Center, Department of Cerebrovascular Surgery, Engineering Research Center of Diagnostic and Therapeutic Technology and Devices for Cerebrovascular Diseases, Ministry of Education, Zhujiang Hospital, Southern Medical University, Guangzhou City, 510280, China.

Observational · n=552

Key points

From the paper's conclusion
  • No statistically significant difference in safety or efficacy was observed between braided and laser-cut stents in acutely ruptured intracranial aneurysms. The interactions with hypertension and irregular morphology warrant attention when individualizing stent selection and planning follow-up angiography. Larger multicenter, adequately powered prospective studies with standardized antithrombotic regimens are needed to validate these findings.

Abstract

PURPOSE: To compare clinical and angiographic outcomes between braided and laser-cut stents in patients with acutely ruptured intracranial aneurysms undergoing stent-assisted coiling (SAC), using propensity score matching (PSM) to adjust for confounders. METHODS: This study analyzed consecutive patients with aneurysmal subarachnoid hemorrhage who underwent SAC within 72 h of onset between January 2017 and June 2024 from a prospectively maintained registry. Clinical and angiographic outcomes were compared before and after 1:1 PSM. Subgroup analyses explored effect modifiers. RESULTS: A total of 552 patients were enrolled (384 laser-cut and 168 braided), with a mean age of 60.32 years and 64.3% females. In the matched cohort (161 pairs), perioperative complications, and aneurysm occlusion and functional outcomes did not differ significantly (all P > 0.05) at 6-month follow-up. In the entire cohort, laser-cut stents were associated with lower odds of favorable functional prognosis at discharge than braided stents (OR = 0.53, 95% CI 0.31-0.89). Significant interactions were observed between stent type and hypertension (P for interaction = 0.009) and irregular aneurysm morphology (P for interaction = 0.010) for incomplete occlusion. CONCLUSION: No statistically significant difference in safety or efficacy was observed between braided and laser-cut stents in acutely ruptured intracranial aneurysms. The interactions with hypertension and irregular morphology warrant attention when individualizing stent selection and planning follow-up angiography. Larger multicenter, adequately powered prospective studies with standardized antithrombotic regimens are needed to validate these findings.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers