Development of a standardized intracranial vessel model from 3D time-of-flight magnetic resonance angiography data of the SHIP cohort.
Antonia Dalmer, Stefan Siewert, Dominique Passler, Hagen Paetow, Christoph Brandt-Wunderlich, Daniel Cantré, Ebba Beller, Sönke Langner,
Institute and Policlinic of Radiology, Pediatric Radiology and Neuroradiology, University Medical Center Rostock, Rostock, Germany. Antonia.Dalmer@med.uni-rostock.de. · Institute for ImplantTechnology and Biomaterials e.V., Rostock-Warnemünde, Germany.
Key points
From the paper's conclusion- Population-based TOF-MRA data can be transformed into a technically robust and anatomically meaningful intracranial reference model suitable for CAD-based simulation and additive manufacturing. The resulting 3D CAD geometry serves as a reusable reference for comparative studies, methodological validation, early-stage device development, and training in endovascular neurosurgery, without aiming to replace patient-specific models.
Abstract
PURPOSE: A standardized, population-based three-dimensional (3D) computer-aided design (CAD) model of the intracranial arterial system was developed from time-of-flight magnetic resonance angiography (TOF-MRA) data of the Study of Health in Pomerania (SHIP) cohort, tailored for realistic simulation and experimental neurovascular applications. METHODS: An averaged intracranial TOF-MRA dataset generated from 4308 individual whole-body MRI examinations of the SHIP cohort was used as the anatomical basis. Intracranial arteries were segmented using 3D Slicer with Frangi-based vessel enhancement, semi-automatic region-growing, and manual refinement to obtain continuous vascular masks. Centerlines were extracted with VMTK (Vascular Modelling Toolkit), and vessel radii were computed via distance mapping. The resulting centerline and radius data were imported into a CAD environment (Creo Parametric) to reconstruct smooth vessel centerlines, generate circular cross-sections, and create a lofted three-dimensional lumen model, which was converted into a hollow geometry with a uniform wall thickness and exported as an STL file for 3D printing. RESULTS: The proposed workflow yielded a geometrically consistent, hollow 3D model of the central intracranial arteries, representing a population-averaged arterial anatomy with smooth vessel courses, gradual diameter transitions, and a closed, continuous wall. The CAD model could be successfully manufactured as a physical 3D-printed phantom and provides a stable, reproducible test environment for digital and in vitro investigations of neurovascular interventions under standardized anatomical conditions. CONCLUSIONS: Population-based TOF-MRA data can be transformed into a technically robust and anatomically meaningful intracranial reference model suitable for CAD-based simulation and additive manufacturing. The resulting 3D CAD geometry serves as a reusable reference for comparative studies, methodological validation, early-stage device development, and training in endovascular neurosurgery, without aiming to replace patient-specific models.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- ArteryX: A Reliable End-To-End Toolbox for Standardized Intracranial Artery Feature Extraction From 3D TOF-MRA.Magnetic resonance in medicine · 2026
- Particle image velocimetry of 3D printed vascular fluidic phantom devices.RSC advances · 2026
- Feasibility of angiographic imaging using fast 3D Magnetic Resonance Spin TomogrAphy in Time-domain (MR-STAT)Magnetic Resonance Materials in Physics Biology and Medicine · 2026
- Intracranial MR Vessel Wall Imaging: Barriers to Clinical Implementation-AJR Expert Panel Review.AJR. American journal of roentgenology · 2026
- Image-Derived 3D Blood-Brain Mechanics: Cerebral Haemodynamics, Brain Motion and In Vivo BenchmarkingbioRxiv · 2026
- SNAPFLOW: A Novel Integrated MRI Sequence for Simultaneous Intracranial Vessel and Blood Flow Assessment.Magnetic resonance in medicine · 2026