Analytical and bioanalytical chemistry

Ultrasonic piezoelectric and heterojunction nanocatalytic probe of MXene@ZrMOF for the RRS determination of carbaryl.

Yujie Chen, Leyao Zhang, Dan Li, Aihui Liang, Guiqing Wen, Zhiliang Jiang

Guangxi Key Laboratory of Environmental Processes and Remediation in Ecologically Fragile Regions, Guangxi Normal University, Guilin, 541004, China. · Guangxi Key Laboratory of Environmental Processes and Remediation in Ecologically Fragile Regions, Guangxi Normal University, Guilin, 541004, China. 244108362@qq.com.

Key points

From the paper's conclusion
  • Therefore, the development of a new ultrasonic piezoelectric nanocatalytic analytical method for detecting trace levels of pesticide residues is of great significance.

Abstract

Ultrasound is the most commonly used means for generating the piezoelectric effect, by which a safe and convenient new approach was provided for the development and application of piezoelectric-nanocatalytic molecular recognition probes. Carbaryl (CB) is a carbamate pesticide that was widely used in agricultural production. Therefore, the development of a new ultrasonic piezoelectric nanocatalytic analytical method for detecting trace levels of pesticide residues is of great significance. In this study, an ultrastrong piezoelectric surface-imprinted nanocatalytic probe of MXene@ZrMOF was prepared. The two piezoelectric fields of MXene and Zr metal-organic framework ZrMOF were coupled with the heterojunction fields to enhance the indicator reaction of HAuCl4-malic acid (MA). The produced gold nanoparticles (AuNP) exhibit strong resonance Rayleigh scattering effect (RRS) at 370 nm. CB could be specifically recognized by the probe, and its catalysis was enhanced linearly. CB can be determined by this RRS method in the concentration range of 3.75-73.75 nmol/L, with a detection limit of 1.19 nmol/L. The method was applied to the determination of CB in pea shoot and tomato samples. For pea shoot samples, the recoveries were 92.0-103.4% with RSDs of 2.43-7.29%; for tomato samples, the recoveries were 90.9-108.1% with RSDs of 2.11-5.42%. Interference tests including inorganic ions, anions, saccharides, vitamin C, glycyrrhizin, other pesticides, and three carbamate pesticides showed no significant interference within ±10% error, demonstrating the good sensitivity and selectivity of the proposed method for CB. This method provides a new analytical approach for pesticide residue analysis.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers