Analytical and bioanalytical chemistry

Matching the binder to the transducer: structural and interfacial determinants of electrochemical biosensors.

Paul Cristian Martian, Mihaela Tertis, Răzvan M Cherecheș, Cecilia Cristea

Department of Analytical Chemistry, Faculty of Pharmacy, Iuliu Hatieganu University of Medicine and Pharmacy, 4 Pasteur St., 400021, Cluj-Napoca, Romania. · Department of Analytical Chemistry, Faculty of Pharmacy, Iuliu Hatieganu University of Medicine and Pharmacy, 4 Pasteur St., 400021, Cluj-Napoca, Romania. mihaela.tertis@umfcluj.ro.

Review

Key points

From the paper's conclusion
  • Particular attention is given to whether the proposed structural advantages of each class are supported by direct electrochemical evidence rather than by cross-study comparisons of detection limits.

Abstract

Electrochemical biosensors do not detect molecular recognition directly, but rather the perturbation that target binding induces at the electrode. In field-effect and other predominantly capacitive transduction formats, this sensing window is strongly constrained by ionic screening and, at physiological ionic strength, by a Debye length of approximately 0.7-1 nm. In faradaic formats, recognition can instead be translated through changes in electron transfer, redox-probe accessibility, reporter position, or catalytic turnover. The type, the dimensions and the immobilisation geometry of the recognition element are therefore important analytical parameters, although their effects depend on the transduction mechanism. This review evaluates fragment antigen-binding (Fab/Fab') and single-chain variable fragments (scFv), nanobodies (VHH), and non-immunoglobulin scaffolds including Anticalins, designed ankyrin repeat proteins (DARPins), Affimers, monobodies and Affibodies, and compares them with full-length antibodies, aptamers, peptides, enzymes and molecularly imprinted polymers (MIPs). Particular attention is given to whether the proposed structural advantages of each class are supported by direct electrochemical evidence rather than by cross-study comparisons of detection limits. On this basis, this review proposes a rational selection framework in which recognition-element architecture is matched to the transduction mechanism, sample matrix, and immobilisation strategy, with particular relevance to point-of-care diagnostics and clinical biomarker detection.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Matching the binder to the transducer: structural and interfacial determinants of electrochemical biosensors — Science Skim