Analytical and bioanalytical chemistry

An enhanced electrochemiluminescence immunosensor based on PtCo/UiO-66-NH2@luminol for highly sensitive detection of recombinant RSV F protein.

Xinyi Yu, Yingqiang Zhang, Qingyang Sun, Jun Cheng, Yuzhu Dai, Weizhong Wang, Zhen Guo

Department of Clinical Laboratory, The 903rd Hospital of the Joint Logistic Support Force, Hangzhou, 310013, China. · Department of Clinical Laboratory, The 903rd Hospital of the Joint Logistic Support Force, Hangzhou, 310013, China. dyz5895@qq.com.

Key points

From the paper's conclusion
  • The immunosensor was fabricated by sequentially assembling chitosan and Ab1 on the Au NPs/GCE, blocking with BSA, capturing RSV F protein, and introducing an Ab2/PtCo/UiO-66-NH2@luminol probe, with Ab1 immobilized by physical adsorption.

Abstract

Respiratory syncytial virus (RSV) causes severe lower respiratory tract infections in infants and young children. The development of sensitive and reliable methods for the detection of RSV proteins is therefore of great significance for disease prevention and control. In this study, a sandwich-type electrochemiluminescence (ECL) biosensor was developed for the highly sensitive detection of recombinant RSV F protein. A glassy carbon electrode (GCE) was modified with gold nanoparticles (Au NPs) to leverage their excellent conductivity and biocompatibility. The Au NPs not only facilitated electron transfer at the electrode interface but also provided a stable platform for immobilizing the capture antibody (Ab1). The immunosensor was fabricated by sequentially assembling chitosan and Ab1 on the Au NPs/GCE, blocking with BSA, capturing RSV F protein, and introducing an Ab2/PtCo/UiO-66-NH2@luminol probe, with Ab1 immobilized by physical adsorption. A multifunctional PtCo/UiO-66-NH2 nanocomposite was further designed, with PtCo providing peroxidase-like catalytic activity and UiO-66-NH2 supplying abundant adsorption sites and amino functional groups. This composite enabled efficient stepwise loading of luminol molecules and detection antibodies (Ab2), thereby achieving cascaded amplification of ECL signals in an H2O2 coreactant system. In the presence of recombinant RSV F protein, a stable "electrode-Ab1-RSV F protein-Ab2-probe" sandwich complex was formed. Under optimized conditions, the ECL intensity showed a good linear relationship with recombinant RSV F protein concentration in the range of 0.1 pg mL-1 to 10 ng mL-1, with a calculated detection limit of 0.025 pg mL-1, experimentally verified at this concentration (n = 6). The proposed biosensor exhibited excellent stability, specificity, and reproducibility, providing a sensitive and reliable proof-of-concept platform for the detection of recombinant RSV F protein, which may serve as a foundation for future clinical validation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers