Sorption-spectrophotometric determination of Ni(II) in natural waters using nitrazine yellow immobilised on a polyamine-modified polyacrylonitrile fibre.
Utkirjon Madatov, Samariddin Rakhimov, Zulayxo Smanova, Jasur Tursunqulov, Feruzakhon Tojiboyeva, Xonzoda Turaeva, Dilbar Shakhidova, Khudayor Rajabov,
Samarkand State University named after Sharof Rashidov, 140104, Samarkand, Uzbekistan. · Department of Pharmaceuticals and Chemistry, Faculty of Medicine, Alfraganus University, 100190, Tashkent, Uzbekistan.
Key points
From the paper's conclusion- A solid-phase sorption-spectrophotometric procedure was developed for the determination of Ni(II) in natural waters using nitrazine yellow (NY) immobilised on PPA-1, an anion-exchange fibre obtained by treating hydroxylamine-activated polyacrylonitrile with polyethylene polyamine.
Abstract
A solid-phase sorption-spectrophotometric procedure was developed for the determination of Ni(II) in natural waters using nitrazine yellow (NY) immobilised on PPA-1, an anion-exchange fibre obtained by treating hydroxylamine-activated polyacrylonitrile with polyethylene polyamine. Reagent immobilisation and Ni(II) binding were characterised by absorption and diffuse-reflectance spectroscopy, Raman spectroscopy, conductometry and scanning electron microscopy with energy-dispersive X-ray analysis (SEM-EDS). In aqueous solution, the absorption maximum of NY shifts from 465 to 583 nm on complexation with Ni(II) (Δλ = 118 nm), whereas on the fibre the Kubelka-Munk maximum shifts from 470 to 620 nm (Δλ = 150 nm), so that the analytical signal is measured where the reagent-loaded blank absorbs only weakly. For the solid-phase determination (50 mL sample, pH 6.4, 0.2000 g of NY-loaded fibre, 10 min contact time, no free reagent added), ΔF(R) at 620 nm was linear in the mass of Ni(II) over 4.2-88.5 µg per 50 mL (84-1770 µg L-1; R2 = 0.9985, ten levels, four replicates each). The limits of detection and quantification (3sy/x/b and 10sy/x/b) were 72 and 240 µg L-1, and the repeatability was 0.1-0.9% (RSD, n = 4). The solution reaction, used only for spectral characterisation, has a molar absorptivity of 3.8 × 104 L mol-1 cm-1 at 583 nm and a Sandell sensitivity of 0.0016 µg cm-2. Cu(II), Fe(II), Fe(III), Zn(II), Mn(II), Co(II), Pb(II) and Hg(II) were tolerated at a tenfold mass excess over Ni(II) (recoveries 99.3-100.0%). Ni(II) added to Zarafshan River water at 400-1000 µg L-1 was recovered at 97.5-104.0% (RSD 4.2-7.3%, n = 5) without significant bias. Because the LOQ exceeds the WHO drinking-water guideline value (70 µg L-1), the procedure in its present form is suited to Ni(II)-contaminated surface waters and wastewaters; monitoring at the guideline level would require prior preconcentration. The procedure is solvent-free and uses an inexpensive, disposable fibrous sensing phase that is easily separated from the sample.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- New Optical Sensing Reagent of Bis(2-oxidobenzylidene)benzenesulfonohydrazide Nickel(II) for the Detection of Formaldehyde in FishMalaysian Journal of Chemistry · 2026
- PPF-1/Ferron-based hybrid sorption–spectrometric method for the sensitive and selective determination of Fe(III)International Journal of Environmental & Analytical Chemistry · 2026
- Characterizing nickel adsorption-desorption on kaoliniteApplied Geochemistry · 2026
- Enhanced Ni(II) Removal from Water Using a Magnetite-Based Hybrid Ion-Exchange Material: Adsorption Performance and Process OptimizationProcesses · 2026
- Solid-phase extraction of organic dyes using a nickel trimesinate-based hybrid metal-organic framework combined with spectrophotometric determinationScientific Reports · 2026
- A Highly Selective Fiber-Optic Surface Plasmon Resonance Sensor Based on an alkaline MXene/Layered Double Hydroxide Hybrid for Trace-Level Detection of Ni(II).Langmuir : the ACS journal of surfaces and colloids · 2026