CHA-mediated split G-quadruplex assembly: a ratiometric AIE strategy for label-free detection of APE1.
Chan Yang, Zihan Yan, Yanru Qin, Ying Wei, Ziyi He, Liuting Mo, Weiying Lin
Institute of Optical Materials and Chemical Biology, Guangxi Key Laboratory of Electrochemical Energy Materials, College of Chemistry and Chemical Engineering, Guangxi University, Nanning, Guangxi, 530004, P. R. China. yangchan361@163.com. · Institute of Optical Materials and Chemical Biology, Guangxi Key Laboratory of Electrochemical Energy Materials, College of Chemistry and Chemical Engineering, Guangxi University, Nanning, Guangxi, 530004, P. R. China.
Key points
From the paper's conclusion- Herein, we develop a label-free ratiometric fluorescent biosensor (TCHG) that integrates APE1-mediated catalytic hairpin assembly (CHA) amplification with split G-quadruplex/malachite green (MG)-mediated aggregation-induced emission (AIE) signaling for sensitive activity analysis of APE1.
Abstract
Apurinic/apyrimidinic endonuclease 1 (APE1), a critical enzyme in the base excision repair pathway, is a potential biomarker for numerous cancer types. Traditional APE1 activity detection methods are hindered by complex protocols, expensive labeling requirements, and vulnerability to environmental factors. Herein, we develop a label-free ratiometric fluorescent biosensor (TCHG) that integrates APE1-mediated catalytic hairpin assembly (CHA) amplification with split G-quadruplex/malachite green (MG)-mediated aggregation-induced emission (AIE) signaling for sensitive activity analysis of APE1. Our system operates through APE1's specific cleavage of apurinic/apyrimidinic (AP) site-containing double-stranded substrates, which releases trigger strands that initiate a CHA cascade. This cascade drives the assembly of split G-quadruplex structures. Upon reconstruction, the complete G-quadruplex binds MG, generating amplified near-infrared fluorescence with AIE characteristics. Simultaneously, Hoechst 33258 (HOE) embedded within double-stranded DNA provides a stable reference signal, enabling self-calibrated ratiometric output that effectively minimizes signal fluctuations from instrumental and environmental variations. The TCHG biosensor demonstrates high selectivity for APE1 with a detection limit of 2.4 × 10-3 U/mL. Importantly, it maintains reliable analytical performance in complex biological matrices, including fetal bovine serum and various cell lysates, successfully differentiating endogenous APE1 activity between normal and cancer cells. The TCHG system offers a tool for APE1 activity analysis in biological samples, with potential applications in biomedical research.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A pH-Responsive and Cofactor-Self-Sufficient DNAzyme@ZIF-8 Probe for Imaging APE1 Activity in Tumor Metastasis and Oxidative Stress.ACS sensors · 2026
- Nanopipette Sensing of APE1 Activity via Enzymatic Recycling and DNA Tetrahedron-Streptavidin Reporting: Profiling in Cancer Diagnostics, Oxidative Stress, and Cell Cycle.Analytical chemistry · 2026
- A ratiometric fluorescence nanosensor based on CdTe QDs for APE1 detection in breast cancer cell lysates.Analytical methods : advancing methods and applications · 2026
- Monitoring of APE1 Activity in the Nuclei and Cytoplasm of Single Living Cells Using an Apurinic/Apyrimidinic Site-Containing DNA-Decorated Nanopore SensorAnalytical Chemistry · 2026
- A signal-on fluorescent probe integrating Au@Ag NPs-based fluorescence resonance energy transfer quenching and enzyme-free catalytic hairpin assembly for c arcinoembryonic antigen detection.Mikrochimica acta · 2026
- AND-Gated Intramolecular Confined CHA Converts Forked DNA Probes into Brushlike Assemblies for Tumor-Cell Imaging.Analytical chemistry · 2026