Development of a certified reference material for polycyclic aromatic hydrocarbons (PAH) in olive oil.
Thomas Sommerfeld, Jan Lisec, Christian Jung, Tatjana Mauch, Juliane Riedel, Sebastian Recknagel, Sibylle Penk, Sabine Buttler,
Bundesanstalt für Materialforschung und -prüfung (BAM), Department of Analytical Chemistry and Reference Materials, Berlin, Germany. · Bundesanstalt für Materialforschung und -prüfung (BAM), Department of Quality Infrastructure, Berlin, Germany.
Key points
From the paper's conclusion- However, no certified reference material (CRM) is currently available containing PAH-4 at the regulated maximum levels.
Abstract
Like all edible vegetable oils, olive oils can be contaminated with lipophilic organic pollutants such as polycyclic aromatic hydrocarbons (PAH). Olive oils are susceptible to PAH contamination, typically due to combined effects including environmental pollution, oil processing, and migration from food contact materials. Monitoring PAH levels in olive oil is therefore essential to ensure food safety and consumer protection. According to Commission Regulation 2023/915, maximum levels have been set for certain PAH: 2 µg kg-1 for benzo[a]pyrene (BaP) and 10 µg kg-1 for PAH-4, representing the sum of BaP, benz[a]anthracene (BaA), benzo[b]fluoranthene (BbF), and chrysene (Chr). However, no certified reference material (CRM) is currently available containing PAH-4 at the regulated maximum levels. To address this deficiency, the first CRM for PAH-4 in extra virgin olive oil (BAM-A001) was developed based on the requirements of ISO 33405. BAM-A001 is intended to be used for performance evaluation and validation of analytical methods for the determination of PAH in olive oil and similar vegetable oils. The entire CRM development process including preparation, homogeneity and stability studies, and value assignment is presented. The certified mass fractions of BaP (1.44 µg kg-1) and PAH-4 (7.33 µg kg-1) were determined upon in-house study at BAM using stable isotope dilution analysis gas chromatography mass spectrometry (SIDA-GC-MS). In addition, BAM-A001 underwent secondary characterization for lead (Pb) and cadmium (Cd) levels, acknowledging an EU regulation allowing a maximum of 0.1 mg kg-1 Pb in oils and fats.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A safer LED-excited spectrofluorometric platform for rapid determination of benzo[a]pyrene in edible oils.Food chemistry · 2026
- Development of a short and sensitive QuEChERS-SPE-GC-MS method for polycyclic aromatic hydrocarbon (PAH) biomonitoring in Perna perna (Linnaeus, 1758) mussels from an oil-impacted tropical estuary.Environmental monitoring and assessment · 2026
- Optimization and Validation of a Modified Quick, Easy, Cheap, Effective, Rugged, and Safe Method Coupled with Gas Chromatography-Tandem Mass Spectrometry for the Determination of Eight Polycyclic Aromatic Hydrocarbons in Essential Oil-Rich Herbal Medicines.Molecules (Basel, Switzerland) · 2026
- Mineral Oils in Olive Oils: Background, Analytical Determination, Sources of Contamination, and Possible Mitigation StrategiesFoods · 2026
- Source apportionment and health risk assessment of PAHs in commercial fish from Al Jubail, Saudi ArabiaScientific Reports · 2026
- Bilary PAH metabolites in Baltic Sea fish as indicators of spatial and temporal contamination trendsEnvironmental Sciences Europe · 2026