Analytical and bioanalytical chemistry

Rapid serum-based differentiation of ovarian tumors and assessment of post-treatment disease-free status using portable Raman spectroscopy and machine learning.

Huan Wang, Jinhong Wang, Xingyue Gong, Yixuan Zhang, Siyuan Zhang, Yimin Han

Department of Gynaecology, The Sixth Affiliated Hospital of Harbin Medical University, 998 Aiying Street, Songbei District, Harbin, Heilongjiang, 150023, People's Republic of China. · Department of Gynaecology, The First Hospital of Harbin, Harbin, Heilongjiang, People's Republic of China.

Computational · n=280

Key points

From the paper's conclusion
  • These findings support portable serum Raman spectroscopy as a rapid, label-free adjunct for ovarian tumor discrimination and cross-sectional assessment of post-treatment disease-free serum phenotypes.

Abstract

Rapid, low-cost tools for ovarian tumor discrimination and post-treatment assessment remain limited because conventional serum biomarkers such as CA125 have suboptimal sensitivity and specificity. Serum contains proteins, lipids, carbohydrates, and nucleic acids that generate disease-related spectrochemical fingerprints, which portable Raman spectroscopy can capture with minimal sample preparation. We investigated serum Raman profiling for ovarian tumor discrimination and cross-sectional characterization of post-treatment disease-free status. Serum samples from 280 participants (85 benign, 82 malignant, and 113 independent follow-up patients) were analyzed over 400-1800 cm⁻1. Candidate regions were re-selected in each training set and represented by local mean intensity or an 11-point local spectral profile (Raw11). Four classifiers were evaluated using fivefold cross-validation, repeated nested fivefold cross-validation, 100 stratified 70:30 holdout repetitions, and label-permutation testing. Raw11 consistently outperformed mean intensity. RBF-SVM showed balanced discrimination and stability (AUC = 0.969, accuracy = 0.940, sensitivity = 0.941, specificity = 0.939), with a repeated holdout AUC of 0.943 ± 0.054 and permutation P = 0.001996. Representative Raman regions were not significantly correlated with continuous CA125, indicating that Raman features were not simple surrogates for CA125. Follow-up samples were strongly distinguishable from active malignancy (RBF-SVM AUC = 0.996) but less separable from benign samples (random forest AUC = 0.840), and frozen benign-malignant models placed them closer to benign spectral space. These findings support portable serum Raman spectroscopy as a rapid, label-free adjunct for ovarian tumor discrimination and cross-sectional assessment of post-treatment disease-free serum phenotypes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers