Development of a sequential digestion workflow for dual-platform microplastic analysis in pasteurized donor human milk using µ-FTIR and Py-GC/MS.
Iffah Madiha Muhamad Shafiry, Nur Rasyiqah Shamsul, Dhea Maisarah Ahmad Nasri, Fikriah Faudzi, Hamizah Ismail, Sabiqah Tuan Anuar, Chingakham Chinglenthoiba, Norafiza Zainuddin
Department of Biomedical Science, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, 25200, Kuantan, Pahang, Malaysia. · Department of Marine Science & Institute of Oceanography and Maritime Studies of Kulliyyah of Science, International Islamic University Malaysia, 25200, Kuantan, Pahang, Malaysia.
Key points
From the paper's conclusion- This study developed and evaluated a sequential digestion and extraction workflow for isolating and characterizing microplastics in pasteurized donor human milk (PDHM).
Abstract
Reliable determination of microplastics in complex biological matrices remains analytically challenging because of high lipid and protein content, low particle abundance, and the risk of polymer degradation during sample preparation. This study developed and evaluated a sequential digestion and extraction workflow for isolating and characterizing microplastics in pasteurized donor human milk (PDHM). The workflow combined hexane-based lipid removal, proteinase K digestion, and controlled hydrogen peroxide treatment. Particle-count recovery was assessed using polypropylene (PP), polyethylene terephthalate (PET), and nylon 6,6 fragments measuring 0.8-1.3 mm. Recoveries ranged from 96.3% to 100%, indicating minimal loss of these fragments during digestion and filtration. The recovered fragments were analyzed by µ-FTIR. Py-GC/MS-based mass recovery was not evaluated because the dimensions of the recovered reference fragments were incompatible with the capacity of the pyrolysis sample cup, precluding their quantitative transfer and analysis. Blank-corrected microplastic abundance in PDHM ranged from 2.3 to 15.3 particles per 30 mL, equivalent to 76.7-509.9 particles L⁻1. µ-FTIR identified polyamide (PA), polyethylene (PE), PET, polyurethane (PU), polytetrafluoroethylene (PTFE), polystyrene (PS), poly(methyl methacrylate) (PMMA), and rayon, predominantly in the <100 µm size class. Py-GC/MS analysis indicated polycarbonate at 1.5 µg per sample in two of the three replicates, whereas the remaining replicate was below the laboratory reporting limit. This finding was interpreted as preliminary because independent peak-level confirmation was not possible using the analytical information available. The developed workflow provides a basis for microplastic isolation and particle-level characterization in PDHM but requires further size- and polymer-specific validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Microplastic contamination in commercial milk: Quantification and polymer identification using SEM-EDS and Micro-Raman spectroscopy.Current research in food science · 2026
- Effects of Chemical Digestion on Polyethylene and Polypropylene Microplastics: Implications for Reliable Food AnalysisApplied Sciences · 2026
- Unified alcoholysis-GC-MS/MS for simultaneous differentiation and quantification of polyester microplastics in water.Talanta · 2026
- Abundance and characterization of microplastics in milk and dairy milk products with a special emphasis on possible health risk assessment: A global systematic review.Journal of hazardous materials · 2026
- A Robust Multistep Digestion Method for Microplastics Detection in Human Tissue by MicroRaman AnalysisDrug Testing and Analysis · 2026
- Zoological biobanks as a resource for microplastic analysis: a Py-GC-MS/MS case study on sea cucumbers.Marine pollution bulletin · 2026