Rapid purity and charge-variant analysis of bispecific antibodies using microfluidic capillary electrophoresis-mass spectrometry.
Ruben Cageling, Karin Lubbers-Geuijen, Govert W Somsen, Kevin Jooß
Protein Purification & Characterization Department, Polpharma Biologics Utrecht, Yalelaan 46, 3584 CM, Utrecht, The Netherlands. · Division of BioAnalytical Chemistry, Department of Chemistry and Pharmaceutical Sciences, Amsterdam Institute for Molecular and Life Sciences (AIMMS), Vrije Universiteit Amsterdam, de Boelelaan 1085, 1081 HV, Amsterdam, The Netherlands.
Key points
From the paper's conclusion- Here, we demonstrate the usefulness of microfluidic capillary electrophoresis-mass spectrometry (MCE-MS) for rapid purity and proteoform profiling of BsAb samples.
Abstract
Bispecific antibody (BsAb) therapeutics have the ability to bind two targets simultaneously, which opens up new pathways for disease treatment. BsAbs consist of distinct heavy and light chains that need to be assembled correctly to form the appropriate heterodimer. However, during development and production, misassembly of chains may occur, which affects BsAb purity, and therefore needs to be monitored. Here, we demonstrate the usefulness of microfluidic capillary electrophoresis-mass spectrometry (MCE-MS) for rapid purity and proteoform profiling of BsAb samples. MCE was capable of resolving homodimeric antibody species as well as charge variants from a model BsAb, while MS detection provided identification of these BsAb charge variants and glycoforms. A low-resolution MCE-MS method allowed quantitative determination of homodimer content in less than 3 min, whereas a high-resolution MCE-MS method delivered the detailed charge-variant and glycoform profile of the BsAb therapeutic within 15 min. We applied both methods in tandem for clone screening and downstream purification monitoring of large biosimilar BsAb sample sets. First, the homodimer-heterodimer ratio of BsAb cell line samples and purification process intermediates was established using the fast MCE-MS method. Next, based on the determined BsAb purity, samples of interest were selected and analyzed with the high-resolution MCE-MS method yielding a quality profile, permitting rational clone selection and optimization of the purification process. Overall, the developed MCE-MS workflow exhibits great potential to accelerate and enhance decision-making during BsAb development and production.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Balancing speed and separation: A high-throughput native mass spectrometry platform for screening complex bispecific antibody variants.Talanta · 2026
- Parallel Sequencing of the Two Arms on a Bispecific Antibody by Electron Capture Dissociation on a timsOmni Platform Reveals Several By-products in the Controlled Fab-arm Exchange ProcessAnalytical Chemistry · 2026
- Recent advances and applications of capillary electrophoresis-sodium dodecyl sulfate for characterization and fragment identification of monoclonal antibodies and their derivativesThe Analyst · 2025
- Development and application of a mechanistic model for protein A resolution of a bispecific antibody for process characterization and optimization.Biotechnology progress · 2026
- Advancing Host Cell Protein Characterization in Monoclonal Antibody Therapeutics: A Nanoparticle-Enriched and High-Sensitivity Mass Spectrometry Approach.Journal of proteome research · 2026
- Tandem-Trapped Ion Mobility Spectrometry as a Platform for Conformationally Resolved Analysis of Protein Complexes and BiologicsAnalytical Chemistry · 2026