International urogynecology journal

A Comprehensive 3D Ultrasound-Based Framework to Quantify Bulkamid® Deposition.

Alireza Hadizadeh, Durwash Badr, Henry H Chill, Sydnei Lewis, Angela Leffelman, Ana Burgos, Claudia Paya-Ten, Cecilia Chang,

Department of Surgery, University of Chicago Medicine, Chicago, IL, USA. ali1375hadi@gmail.com. · Departments of Bioengineering and Obstetrics, Gynecology, and Reproductive Sciences, University of Pittsburgh, Pittsburgh, PA, USA.

Observational · n=31

Key points

From the paper's conclusion
  • This study presents a comprehensive 3D ultrasound-based framework for quantifying the spatial distribution of Bulkamid® within the urethra. Exploratory 3D analyses identified the associations of a higher volumetric ratio and more circumferentially symmetric distribution with clinical improvement after urethral bulking. These preliminary spatial patterns warrant prospective validation in a larger cohort.

Abstract

INTRODUCTION AND HYPOTHESIS: Urethral bulking with Bulkamid® (polyacrylamide hydrogel) is a minimally invasive treatment for stress urinary incontinence (SUI), but methods for quantitatively characterizing its three-dimensional spatial distribution are limited. This study establishes a 3D ultrasound-based framework to quantify Bulkamid® deposition geometry and evaluates whether spatial distribution metrics differ according to clinical improvement. METHODS: In this single-center longitudinal study, women with confirmed SUI who underwent urethral bulking between 2023 and 2025 were followed at 6-12 months. Endovaginal 3D ultrasound volumes were segmented and analyzed across three spatial domains: axial (longitudinal localization), circumferential (quadrant-based distribution and opposition metric), and radial (density-weighted coaptation metric). Clinical comparisons were performed as exploratory secondary analyses, where clinical improvement was defined as a PGI-I score of 1-2 together with a >50% reduction in SUI episodes from baseline. RESULTS: A total of 31 patients were included. The proposed framework enabled quantification of total and relative Bulkamid® volume, longitudinal localization, quadrant-based circumferential distribution, opposition, and radial coaptation. In exploratory analysis of clinical outcomes, a higher Bulkamid®-to-urethral volume ratio (0.16 ± 0.07 vs 0.10 ± 0.06; p = 0.03) and greater fourth-quadrant volume (126.0 ± 108.1 vs 56.9 ± 45.1 cm3; p = 0.03) were associated with clinical improvement. Other spatial metrics showed descriptive trends only. CONCLUSION: This study presents a comprehensive 3D ultrasound-based framework for quantifying the spatial distribution of Bulkamid® within the urethra. Exploratory 3D analyses identified the associations of a higher volumetric ratio and more circumferentially symmetric distribution with clinical improvement after urethral bulking. These preliminary spatial patterns warrant prospective validation in a larger cohort.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A Comprehensive 3D Ultrasound-Based Framework to Quantify Bulkamid® Deposition — Science Skim