Radiologie (Heidelberg, Germany)

Spleen-corrected MRI signal intensity parameters for predicting posthepatectomy liver failure in hepatocellular carcinoma.

Sirui Yang, Huimin Dong, Shua Cui, Peipei Ye, Yupeng Zeng, Li Guo

Department of Radiology, The Second Affiliated Hospital of Kunming Medical University, 374 Dianmian Avenue, 650101, Wuhua District, Kunming, Yunnan, China. · Department of Radiology, The Second Affiliated Hospital of Kunming Medical University, 374 Dianmian Avenue, 650101, Wuhua District, Kunming, Yunnan, China. guolab6666@163.com.

Observational · n=233

Key points

From the paper's conclusion
  • Spleen-corrected parameters provide robust PHLF prediction. SI-HEF offers high sensitivity and complements conventional indices, and its integration with clinical variables improves preoperative risk stratification.

Abstract

OBJECTIVE: To evaluate two spleen-corrected signal intensity parameters, the signal intensity-based corrected hepatocellular enhancement index (SI-CHEI) and signal intensity-based hepatocellular enhancement fraction (SI-HEF), for predicting posthepatectomy liver failure (PHLF) in hepatocellular carcinoma (HCC) using gadoxetic acid disodium (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI). MATERIALS AND METHODS: This retrospective study included 233 patients with HCC who underwent Gd-EOB-DTPA-enhanced MRI before hepatectomy. Patients were divided into training (n = 163) and test (n = 70) groups. Signal intensity was measured in liver and spleen on precontrast and hepatobiliary-phase images. A two-compartment model was used to calculate SI-CHEI and SI-HEF. Predictive performance was assessed with receiver operating characteristic analysis and multivariable logistic regression. RESULTS: In total, 65 patients (27.9%) developed PHLF. The area under the curve (AUC) values for SI-HEF were 0.759 (95% confidence interval [CI]: 0.673-0.837) and 0.760 (95% CI: 0.634-0.870) in the training and test groups, respectively. For SI-CHEI, AUCs were 0.721 (95% CI: 0.628-0.811) and 0.721 (95% CI: 0.599-0.842). The liver-to-spleen ratio was 0.737 (95% CI; 0.637-0.826). SI-HEF had the highest sensitivity (0.810) and negative predictive value (0.889). SI-HEF values were lower in patients with grades B and C PHLF than those with grade A PHLF (P = 0.041); SI-CHEI showed no difference. A multivariable nomogram integrating clinical and volumetric variables with SI-HEF showed AUCs of 0.891 (95% CI: 0.841-0.940) and 0.881 (95% CI: 0.784-0.979); SI-HEF was the largest contributor to model predictions. CONCLUSION: Spleen-corrected parameters provide robust PHLF prediction. SI-HEF offers high sensitivity and complements conventional indices, and its integration with clinical variables improves preoperative risk stratification.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers