Comparison of the shetty test and ottawa ankle rules for foot and ankle fractures in the emergency department: a prospective validation study.
Ihsan Gumustas, Ertugrul Altinbilek, Hatice Topcu, Abdullah Avlac, Andac Oztekin, Muhammet Karaketir, Neva Ozturker
Emergency Medicine Clinic, Medipol Mega Hospital, Istanbul, Bagcilar, 34214, Türkiye. ihsangumustas@gmail.com. · Emergency Medicine Clinic, Istanbul Hamidiye Etfal Training and Research Hospital, University of Health Sciences, Istanbul, 34200, Türkiye.
Key points
From the paper's conclusion- The Shetty test did not reproduce the sensitivity reported in its derivation study and missed nearly a quarter of fractures, all requiring immobilisation. It cannot be recommended as a stand-alone tool to exclude foot and ankle fracture; its higher specificity may justify evaluation as an adjunct applied after, not instead of, the OAR.
Abstract
PURPOSE: The Shetty test has been proposed as a simpler alternative to the Ottawa Ankle Rules (OAR) for excluding fracture in foot and ankle trauma and was reported to have perfect sensitivity in its derivation study. We compared its diagnostic accuracy with that of the OAR against imaging in an emergency department population. METHODS: One hundred consecutive patients with acute foot and/or ankle trauma were enrolled after at least one of two attending physicians judged radiography indicated. Both index tests were performed independently by two blinded emergency physicians; where they differed, the patient was classified positive if either was positive. The reference standard was fracture on radiography, or on CT obtained on clinical suspicion. McNemar and DeLong tests were used, and inter-test agreement Cohen kappa. RESULTS: Fractures occurred in 26 patients (26%); 8 (30.8%) were occult, detected only on CT. The Shetty test had lower sensitivity than the OAR (76.9% vs. 92.3%) but higher specificity (67.6% vs. 18.9%). It missed 6 of 26 fractures, including two talar and one base-of-fifth-metatarsal fracture, all of which were managed with plaster-splint immobilisation. Used alone it would have avoided 56 radiographs while missing 6 fractures, versus 16 avoided and 2 missed for the OAR. Agreement was poor (kappa 0.19). CONCLUSION: The Shetty test did not reproduce the sensitivity reported in its derivation study and missed nearly a quarter of fractures, all requiring immobilisation. It cannot be recommended as a stand-alone tool to exclude foot and ankle fracture; its higher specificity may justify evaluation as an adjunct applied after, not instead of, the OAR.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic Accuracy of Artificial Intelligence Versus Musculoskeletal Radiologists for Foot and Ankle Fracture Detection on Radiographs.Diagnostics (Basel, Switzerland) · 2026
- Clinical Decision Rules and Reduction of Ankle X-Rays in Pediatric Population: An Intervention Study.Journal of emergency nursing · 2026
- Independent bone-level diagnostic accuracy study of an AI tool for detecting appendicular skeletal fractures on radiographsEuropean Radiology · 2026
- Additional Fracture Detection by Computed Tomography After Plain Radiography in Adults with Isolated Foot and Ankle Trauma: A Retrospective Selected-Cohort Study.Journal of clinical medicine · 2026
- Emergency department ankle burden score (ED-ABS): A bedside injury-burden score for acute ankle trauma.The American journal of emergency medicine · 2026
- Performance of artificial intelligence for fracture detection: an umbrella review and second-order-meta-analysisnpj Digital Medicine · 2026