Impact of PET/CT imaging on target volume delineation and radiotherapy planning in patients with locally advanced esophageal cancer.
Vera Ashykhmina, Arpad Dezsö, André Glowka, Tatiana Lushchaeva, Pauline Riethmueller, Stanislav Tchaikovski, Daniel Medenwald
Department of Radiation Oncology, Otto-von-Guericke University Magdeburg, Leipziger Str. 44, 39120, Magdeburg, Germany. vera.ashykhmina@gmail.com. · Department of Radiation Oncology, Otto-von-Guericke University Magdeburg, Leipziger Str. 44, 39120, Magdeburg, Germany.
Key points
From the paper's conclusion- We performed a retrospective study evaluating the impact of PET/CT-guided contouring on target volume size, target volume geometry, organ-at-risk exposure, and interobserver variability compared with conventional CT-based delineation in 20 patients with locally advanced esophageal cancer.
- PET/CT-based planning significantly reduced PTV volumes (from 602.3 ± 267.4 cm3 to 453.2 ± 237.4 cm3, p < 0.001). In four patients (20%), more than 100 cm3 of the PET-defined target volume was located outside the original CT-based PTV. Eight patients (40%) showed HD95 values exceeding 25 mm between CT- and PET/CT-based target volumes. PET/CT-based planning also reduced pulmonary radiation exposure (lung V20 decreased from 10.39 ± 1.23% to 7.85 ± 1.18%, p = 0.001; lung V30 decreased from 4.41 ± 0.76% to 2.46 ± 0.37%, p = 0.003).
- PET/CT-guided radiotherapy planning substantially influences target volume geometry in esophageal cancer and enables identification of metabolically active disease not adequately covered by CT-based planning alone. Prospective studies are warranted to determine whether these geometric and dosimetric advantages translate into improved oncologic outcomes and reduced treatment-related toxicity.
Abstract
BACKGROUND AND PURPOSE: Combined chemoradiotherapy is a key treatment strategy for esophageal cancer in both neoadjuvant and definitive settings. Accurate and consistent target volume delineation is essential to optimize therapeutic efficacy and minimize toxicity. 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) enables visualization of metabolically active tumor regions and may improve the accuracy and reproducibility of target volume definition. This retrospective study aimed to evaluate the impact of PET/CT-guided contouring on target volume size, target volume geometry, organ-at-risk exposure, and interobserver variability compared with conventional CT-based delineation. MATERIALS AND METHODS: Twenty patients treated between 2022 and 2024 at the Department of Radiation Oncology, University Hospital Magdeburg, were included. Gross tumor volumes (GTVs) were independently delineated on CT and PET/CT datasets. Clinical target volumes (CTVs) and planning target volumes (PTVs) were subsequently generated. Geometric agreement was assessed using the Dice similarity coefficient (DSC) and 95th percentile Hausdorff distance (HD95). Interobserver variability was evaluated using simultaneous truth and performance level estimation (STAPLE)-generated reference contours. Paired t‑tests (α = 0.05) were used to assess volumetric and dosimetric differences. RESULTS: PET/CT-based planning significantly reduced PTV volumes, with mean PTV decreasing from 602.3 ± 267.4 cm3 to 453.2 ± 237.4 cm3 (p < 0.001). In four patients (20%), more than 100 cm3 of the PET-defined target volume was located outside the original CT-based PTV, indicating clinically relevant geometric modification of irradiation fields. Eight patients (40%) showed HD95 values exceeding 25 mm between CT- and PET/CT-based target volumes. PET/CT-based planning also reduced pulmonary radiation exposure, with lung V20 decreasing from 10.39 ± 1.23% to 7.85 ± 1.18% (p = 0.001) and lung V30 from 4.41 ± 0.76% to 2.46 ± 0.37% (p = 0.003). No significant reduction in cardiac or left anterior descending coronary artery (LAD) exposure was observed. Interobserver analysis demonstrated comparable overall agreement between CT- and PET/CT-based contouring, with lower HD95 variability for PET/CT-based delineation. CONCLUSION: PET/CT-guided radiotherapy planning substantially influences target volume geometry in esophageal cancer and enables identification of metabolically active disease not adequately covered by CT-based planning alone. In addition to significant target volume reduction and lower pulmonary dose exposure, PET/CT-based contouring may support more consistent target volume delineation. Prospective studies are warranted to determine whether these geometric and dosimetric advantages translate into improved oncologic outcomes and reduced treatment-related toxicity.
Read the paper
Discussion · 1
Science Skim's AI key points, plus readers' public thoughts
- We performed a retrospective study evaluating the impact of PET/CT-guided contouring on target volume size, target volume geometry, organ-at-risk exposure, and interobserver variability compared with conventional CT-based delineation in 20 patients with locally advanced esophageal cancer.
- PET/CT-based planning significantly reduced PTV volumes (from 602.3 ± 267.4 cm3 to 453.2 ± 237.4 cm3, p < 0.001). In four patients (20%), more than 100 cm3 of the PET-defined target volume was located outside the original CT-based PTV. Eight patients (40%) showed HD95 values exceeding 25 mm between CT- and PET/CT-based target volumes. PET/CT-based planning also reduced pulmonary radiation exposure (lung V20 decreased from 10.39 ± 1.23% to 7.85 ± 1.18%, p = 0.001; lung V30 decreased from 4.41 ± 0.76% to 2.46 ± 0.37%, p = 0.003).
- PET/CT-guided radiotherapy planning substantially influences target volume geometry in esophageal cancer and enables identification of metabolically active disease not adequately covered by CT-based planning alone. Prospective studies are warranted to determine whether these geometric and dosimetric advantages translate into improved oncologic outcomes and reduced treatment-related toxicity.
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of PET-detected nodal upstaging and planning target volume expansion in esophageal cancer radiotherapy planning.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2026
- Reproducibility of 18F-FDG PET/CT-based tumour and nodal target delineation in stage II-III breast cancer.Radiation oncology (London, England) · 2026
- 18F-FDG PET-CT- vs. CT-Based Radiotherapy Treatment Planning for Head and Neck CancerLife · 2026
- Prognostic Value of Pretreatment [18F]FDG PET/CT Metabolic Parameters for Overall Survival in Esophageal Cancer: A Single-Center Retrospective Cohort with Long-Term Follow-Up.Diagnostics (Basel, Switzerland) · 2026
- Utilization of 68Ga-FAPI PET/CT improves the gross tumor volume delineation in nasopharyngeal carcinoma within a safe radiation dose to organs at risk.Quantitative imaging in medicine and surgery · 2026
- Comparing the utility of FDG PET-CT and contrast-enhanced CT in patients with oesophagogastric adenocarcinoma treated with neoadjuvant chemotherapy.European radiology · 2026