Water environment research : a research publication of the Water Environment Federation

Concurrent Classification of Pseudomonas aeruginosa Occurrence From Routine Municipal Swimming-Pool Monitoring Data: An Explainable Machine-Learning Proof-of-Concept With Grouped Validation.

Athanasia Palaiologou, Maria Athanasiou, Apostolos Vantarakis

Department of Public Health, School of Medicine, University of Patras, Patras, Greece.

Observational · n=453

Key points

From the paper's conclusion
  • These results support exploratory concurrent classification, not prospective warning or deployment readiness, and highlight the need for independent multifacility validation.

Abstract

Routine swimming-pool surveillance may support detection-oriented screening, but rare positives and repeated sampling complicate model validation. This retrospective study analyzed 453 samples (37 occurrence-positive) from four chlorinated pools in two Greek facilities (2022-2025). Random forest, logistic regression, gradient boosting, and extra trees were evaluated using concurrent monitoring variables, physicochemical predictors and previous-sample information. Row-level, leave-one-pool-out, leave-one-facility-out and temporal validation were compared with a residual-chlorine-only baseline. Full-monitoring random forest achieved PR-AUC 0.532 within the network, decreasing to 0.386 for held-out pools and 0.157 for a held-out facility; corresponding logistic-regression values were 0.525 and 0.326. Residual chlorine alone achieved PR-AUC 0.452, with no model significantly outperforming it. Previous-sample predictors provided no convincing early-warning signal. Screening thresholds yielded substantial false alerts. These results support exploratory concurrent classification, not prospective warning or deployment readiness, and highlight the need for independent multifacility validation. Machine-learning models classified Pseudomonas aeruginosa occurrence from routine swimming-pool monitoring data within the observed network, but performance fell in pools and facilities not used for training, and no model clearly outperformed residual chlorine alone. Previous-sample data gave no convincing early warning, so prospective multifacility validation is needed.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Concurrent Classification of Pseudomonas aeruginosa Occurrence From Routine Municipal Swimming-Pool Monitoring Data: An Explainable Machine-Learning Proof-of-Concept With Grouped Validation — Science Skim