Study on Field Distortion and Surface Flashover Characteristics of Epoxy Glass Fiber under Low‐Temperature Gradient
Yongqiang Fan, Shuhan Peng, Jianzhong Yang, Aoqi Jia, Yun Bai, Zhihui Li, Xiaoyun Tian, Yonggang Yue
Key points
From the paper's conclusion- These findings provide quantitative experimental data and mechanistic insight for the insulation design of superconducting terminals. © 2026 Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.
Abstract
The terminal insulation of superconducting power equipment operates in environments characterized by low temperatures and large temperature gradients, making its surface flashover characteristics a critical factor that limits system reliability. In this study, a low‐temperature gradient flashover test platform was developed to investigate the flashover voltage and its underlying trends in glass‐fiber‐reinforced epoxy (GFRP) across various temperature differences (ΔT = 0–100 K). A charge migration model, previously validated in our work on trap characteristics, was employed to aid in interpreting the experimental results. The results indicate that low temperatures inherently suppress flashover; specifically, the isothermal flashover voltage at 193 K is 16.15% higher than that at 293 K. However, the introduction of a temperature gradient significantly reduces the flashover voltage. At ΔT =100 K, the flashover voltage drops to merely 75.13% of its isothermal counterpart, and the partial discharge inception voltage decreases by 24.62%. Simulation analysis reveals that this reduction is due to severe electric field distortion at the high‐voltage terminal: 80.67% of the total voltage drops within the first 2 mm, and the tangential surface electric field is amplified eightfold. These findings provide quantitative experimental data and mechanistic insight for the insulation design of superconducting terminals. © 2026 Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Surface Flashover in 50 Years: III. Extreme Environments and Industrial ChallengesHigh Voltage · 2026
- From Thermal Ablation to Mechanical Fracture: Lightning-Caused Breakage of Insulated Conductors Under Thermal–Mechanical Coupling of Power-Frequency Follow Current ArcsEng · 2026
- A Thermal‐Dependent Conductivity Coating for Surface Charge and Electric Field Mitigation Under Electrothermal Coupling FieldHigh Voltage · 2026
- Low-Temperature Negative Lightning Impulse Breakdown in Ester and Mineral Oils: Viscosity–Voltage Correlation and Streamer BranchingIEEE Transactions on Dielectrics and Electrical Insulation · 2026
- Investigation of the Discharge Characteristics Induced by Free Metallic Particles on Insulation Surfaces Under Low-Pressure ConditionsEnergies · 2026
- Surface Erosion-Corona Synergistic Degradation Characteristics and Material Adaptability of High-Temperature Vulcanized Silicone Rubber in Desert Regions.Polymers · 2026