SEPARATION SCIENCE PLUS

Analytical Quality by Design Guided Development of a Sustainable LC–MS Compatible Reverse Phase HPLC Method for Low‐Level Quantification of Lifitegrast and Bromfenac in Ophthalmic Formulations and Simulated Tear Fluid

Likhit Mandal, Praveen Kumar Vemuri, Manikanta Murahari, Sunil Tiwari

Key points

From the paper's conclusion
  • Overall, the study provides a validated and practically applicable chromatographic procedure for routine analysis of lifitegrast and bromfenac, with additional potential for further matrix‐based investigations.

Abstract

A single chromatographic method for ophthalmic drugs can simplify routine quality‐control testing and avoid the use of separate procedures. In this study, an analytical quality by design guided reverse phase‐HPLC method was developed for the simultaneous determination of lifitegrast and bromfenac in ophthalmic formulations. The method was developed against predefined requirements for accuracy, precision, resolution, and retention time, with organic‐phase composition, column temperature, flow rate, and mobile‐phase pH investigated through designed experiments. Statistical modeling was subsequently used to establish the method operable design region. Lifitegrast and bromfenac were eluted at approximately 5.5 and 12.6 min, respectively, with satisfactory separation from degradation products. The method showed good linearity, with correlation coefficients of 0.9999 and 0.9994 for lifitegrast and bromfenac, respectively, and limit of quantitation of 0.02 µg/mL for both analytes. Accuracy across the investigated levels was within 98%–102%, while precision remained low, with percentage relative standard deviation values below the predefined acceptance criteria. Forced‐degradation studies demonstrated the ability of the method to distinguish the drug peaks from degradation products. The method was also examined under simulated tear‐fluid and ophthalmic formulation conditions using liquid chromatography–high resolution mass spectrometry, where matrix effects remained close to 100%. Sustainability and practical applicability were assessed using analytical eco‐scale, analytical GREEnness metric approach, green analytical procedure index, blue applicability grade index, and white analytical chemistry approaches. Overall, the study provides a validated and practically applicable chromatographic procedure for routine analysis of lifitegrast and bromfenac, with additional potential for further matrix‐based investigations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers