Rigid Bis-Amidinium Anchoring Engineering Enables Synergistic Defect Suppression and Ion Stabilization for High-Performance Flexible Perovskite X-Ray Detectors and TFT-Array Imaging.
Haojin Li, Danhong Cheng, Xinyue Ma, Xinmei Liu, Tinghuan Yang, Xinyi Geng, Ye Yang, Nan He,
Key Laboratory of Applied Surface and Colloid Chemistry, National Ministry of Education, School of Materials Science and Engineering, Shaanxi Normal University, Xi'an, China. · Frontier Institute of Science and Technology, Shaanxi Key Laboratory of New Conceptual, Sensors and Molecular Materials, Xi'an Jiaotong University, Xi'an, P. R. China.
Key points
From the paper's conclusion- These results demonstrate a transferable molecular-regulation strategy for stabilizing polycrystalline perovskite X-ray detectors across flexible and array-integrated architectures.
Abstract
Flexible direct-conversion X-ray detectors based on halide perovskites hold great promise for mechanically compliant and array-integrated imaging, yet their performance is limited by grain-boundary defects and electrical instability in polycrystalline thick films. Here, we introduce 1,4-benzenedicarboximidamide dihydrochloride (p-BDAm) as an additive for regulating polycrystalline methylammonium lead iodide (MAPbI3) detector layers. Spectroscopic measurements and density functional theory (DFT) calculations support multisite interactions between the bis-amidinium framework and Pb-I-containing species as a plausible contribution to the p-BDAm-mediated regulation of the local grain-boundary environment and crystallization behavior. Overall, p-BDAm incorporation suppresses nonradiative recombination, increases the resistivity and mobility-lifetime product, raises the apparent activation energy extracted from temperature-dependent conductivity from 0.17 to 0.49 eV, and substantially improves dark-current stability. The optimized flexible perovskite composite membrane detector achieves a sensitivity of 2165.5 µC Gyair -1 cm-2 at 10 V and an estimated detection limit of 15.0 nGyair s-1. Moreover, the p-BDAm-regulated MAPbI3 layer is compatible with thin-film transistor (TFT)-array integration, enabling parallel X-ray imaging. A representative TFT image was obtained at an X-ray dose rate of 12.3 µGyair s-1 with an exposure time of 0.5 s. These results demonstrate a transferable molecular-regulation strategy for stabilizing polycrystalline perovskite X-ray detectors across flexible and array-integrated architectures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Physical and Chemical Reinforcement of Polycrystalline Perovskite Films Enables Robust X‐ray Detectors With Low Detection LimitsLaser & Photonics Reviews · 2026
- Tridentate Chelation Coordinated Bismuth Halide Perovskite for High-Performance X-ray Detection.The journal of physical chemistry letters · 2026
- Paper-based lead-free thin film X-ray detectors with high sensitivity and superior environmental stability.Npj flexible electronics · 2026
- 2D Halide Perovskite Single Crystals Constructed by Aromatic Diammonium for High Sensitivity and Low Detection Limit X-Ray Detectors.Advanced materials (Deerfield Beach, Fla.) · 2026
- Suppression of Ion Migration With a Composite Polymer Film in Perovskite Single‐crystal Photodetectors for Sensitive and Stable X‐Ray ImagingLaser & Photonics Review · 2026
- Dual‐Grain‐Size Microcrystal Architectures for Stress‐Regulated Lead‐Free Perovskite Thick‐Film X‐Ray DetectorsAdvanced Functional Materials · 2026