Hierarchically Engineered MXene/CMC-Na Composites with Acetaminophen Modification for Self-Powered Humidity Sensing.
Yang-Sheng Wang, Jin-Xia Jiang, Di-Wen Jiang, Xiang Xu, Hao-Wen Zhang, Hao Chen, Ying Zhi, Li Wang,
School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu, People's Republic of China. · Engineering Research Center for Digital and Intelligent Biomedical Equipment and Novel Dosage Forms, Chongqing Medical and Pharmaceutical College, Chongqing, People's Republic of China.
Key points
From the paper's conclusion- Collectively, the AHMC‐based sensors demonstrate substantial potential for advancing applications in healthcare monitoring, non‐contact humidity detection, and self‐powered systems.
Abstract
Humidity sensors have demonstrated significant potential for applications in wearable electronics, physiological monitoring, and environmental sensing. However, the practical implementation of humidity sensors is often limited by reliance on external power sources, making the development of self-powered humidity sensing systems a considerable challenge. This work presents a hierarchical multi-step modification strategy to fabricate an acetaminophen (AP)-modified hydroxylated MXene/carboxymethylcellulose sodium (CMC-Na) hybrid gel ink (AHMC) with integrated humidity sensing and self-powered functionality. Theoretical calculations reveal that AHMC exhibits exceptional water adsorption capacity, characterized by a lower adsorption energy (-0.42 eV) and a shorter adsorption distance (1.69 Å) compared to MXene. The screen-printed paper-based AHMC humidity sensor (PB-AHMC) demonstrates a rapid capacitive response (4.8/0.6 s) and remarkable response (73524%) with excellent bending stability and environmental durability. Furthermore, the PB-AHMC-based humidity sensor array (PCSA) accurately identifies various subtle respiratory abnormalities with the incorporation of machine learning algorithms. Significantly, a self-powered sensor (SP-AHMC) driven by redox reactions has been developed, achieving a broad detection range (11%-97% RH), exhibiting minimal hysteresis (1.0% RH), and delivering a peak output voltage of 0.43 V at 97% RH. Collectively, the AHMC-based sensors demonstrate substantial potential for advancing applications in healthcare monitoring, non-contact humidity detection, and self-powered systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biodegradable, self-powered E-skin for contactless respiratory and epidermal humidity monitoringSoft Science · 2025
- Flexible, Stretchable, and Self-Healing MXene-Based Conductive Hydrogels for Human Health MonitoringPolymers · 2025
- Rapid Water-Responsive Shape-Memory Nanocellulose/MXene Aerogel for Piezoresistive Sensing and Electromagnetic Interference Shielding in Underwater EnvironmentsACS Applied Polymer Materials · 2025
- Mechanically Resilient Bioinspired Aerogels Enabled by Cross-Scale Interfacial Engineering for Multifunctional Wearable Electronics.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Machine-learning-enabled starch/MXene moisture sensing bioelectronics for human monitoring and interactionChemical Engineering Journal · 2026
- Interface-Regulated Humidity-Sensing Transparent Flexible Film: Antibacterial Properties Facilitate Human-Computer Interaction and Health Monitoring.ACS applied materials & interfaces · 2026