Rescue Diagnosis of Upper-Lobar Station 12U Lymph Nodes Using the Thin Convex-Probe EBUS Bronchoscope (BF-UCP190F): A Report of Two Cases.
Toki Kitano, Yuki Takigawa, Ken Sato, Mayu Goda, Hitoshi Hara, Tomoya Osedo, Yuto Sasano, Keisuke Shiraha,
Department of Respiratory Medicine NHO Okayama Medical Center Okayama Japan.
Key points
From the paper's conclusion- We report two cases in which TCP-EBUS enabled successful endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of the upper-lobar station 12U lymph node (#12U LN) via B3 after conventional bronchoscopic forceps sampling failed to provide a definitive diagnosis.
Abstract
BF-UCP190F (Olympus) is a newly developed thin convex-probe endobronchial ultrasound (TCP-EBUS) bronchoscope, improving access to distal bronchi. We report two cases in which TCP-EBUS enabled successful endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of the upper-lobar station 12U lymph node (#12U LN) via B3 after conventional bronchoscopic forceps sampling failed to provide a definitive diagnosis. In the first case, forceps biopsy of a left upper lobe tumour was non-diagnostic; TCP-EBUS-guided EBUS-TBNA of the left #12U LN established lung adenocarcinoma with N1 involvement. In the second case, the initial bronchoscopy yielded only cytological evidence of carcinoma without histological confirmation; TCP-EBUS-guided sampling of the right #12U LN revealed metastatic small cell carcinoma. In both cases, the pathological diagnosis of EBUS-TBNA guided subsequent treatment. These cases suggest that BF-UCP190F expands the diagnostic range of bronchoscopy and may serve as a valuable rescue technique for sampling upper lobar hilar lymph nodes in clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prospective Case Series to Determine the Feasibility, Diagnostic Yield and Safety of Performing EBUS Guided Trans-Bronchial Mediastinal Cryobiopsy (EBUS-TBMC) of Lymph Nodes Using 1.1 mm Cryoprobe Through a Working Channel of Linear EBUS Bronchoscope Versus Conventional En-Bloc Cryobiopsy.Respirology case reports · 2026
- Tracheal Schwannoma Diagnosed by Endobronchial Ultrasound-Guided Intranodal Forceps Biopsy (EBUS-IFB).Respirology case reports · 2026
- Endobronchial ultrasound-guided mediastinal biopsies for the diagnosis of mediastinal diseases: A network meta-analysisPulmonology · 2026
- Transbronchial Mediastinal Cryobiopsy Guided by Endobronchial Ultrasound in Addition to Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration in the Diagnosis of Ilo-Mediastinal Lymphadenopathy Without Obvious Primary Lung Neoplastic Lesion: A Prospective Multicenter StudyJournal of Clinical Medicine · 2025
- CellVizio® System for Mesothorax Lymphadenopathy Rapid on Site, 18G needle: Pros and ConsJournal of Cancer · 2026
- Primary Mediastinal T-Lymphoblastic Lymphoma With Airway Stenosis Diagnosed Using Endobronchial Ultrasound-Guided Transbronchial Mediastinal Cryobiopsy: A Case Report.Respirology case reports · 2026