Effects of MXD6 and MXD10 on the Toughness and Hydrogen Barrier Properties of PA6 / POE ‐ g ‐ MAH Blend for Type IV Hydrogen Storage Vessel Liners
Zhimin Li, Bo Zhu, Anping Zhu, Jigang Hao, Yuqi Zhao, Yishi Wang, Wei Wang, Mingzhe Zhou,
Key points
From the paper's conclusion- Thus, S80E20DT20 offers substantially improved ductility, higher impact strength at −30°C, a still‐high impact strength at 23°C despite a reduction, and only marginally lower hydrogen barrier performance than S80E20DS20, meeting the hydrogen permeability requirement stipulated in GB/T 42612‐2023.
Abstract
Type IV hydrogen storage vessel liners demand balanced hydrogen barrier, toughness, and hygroscopicity. Semi‐aromatic nylons poly(m‐xylylene adipamide) (MXD6) and poly(m‐xylylene sebacamide) (MXD10) were introduced into PA6/POE‐g‐MAH (80/20, S80E20) by melt‐blending, yielding the PA6/POE‐g‐MAH/MXD6, and PA6/POE‐g‐MAH/MXD10 blends, respectively. With increasing MXD6 content, tensile and bending strengths and modulus all increase, whereas with MXD10 content they first rise and then fall. Impact strengths at 23°C and −30°C decrease yet remain far above neat PA6, and elongation at break declines sharply for the PA6/POE‐g‐MAH/MXD6 blends, but only mildly for the PA6/POE‐g‐MAH/MXD10 blends. At 20 wt%, PA6/POE‐g‐MAH/MXD6 (80/20/20, S80E20DS20) exhibits impact strengths of 66.2 kJ/m 2 (23°C) and 17.46 kJ/m 2 (−30°C) with an elongation at break of 72.49%, whereas PA6/POE‐g‐MAH/MXD10 (80/20/20, S80E20DT20) shows 54.66 and 21.53 kJ/m 2 with a substantially higher elongation of 181.29%. Hydrogen permeability coefficients of S80E20DS20 and S80E20DT20 are 3.89 × 10 −14 and 3.98 × 10 −14 cm 3 ·cm/(cm 2 ·s·Pa)—reductions of 11.99% and 9.95% over S80E20 blend (4.42 × 10 −14 ), yet above neat PA6 (2.82 × 10 −14 ). Both blends show lower hygroscopicity than neat PA6 and S80E20. Thus, S80E20DT20 offers substantially improved ductility, higher impact strength at −30°C, a still‐high impact strength at 23°C despite a reduction, and only marginally lower hydrogen barrier performance than S80E20DS20, meeting the hydrogen permeability requirement stipulated in GB/T 42612‐2023. This ternary blending strategy provides a promising route to high‐performance PA6 liners.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hydrogen Permeation Behavior of Locally Reinforced Type IV Hydrogen Storage VesselsPolymers · 2026
- Hydrogen permeability of reinforced polyamide 12 composites modified with carbon nanotubes for barrier lining applications in pipelines and storage tanksInternational Journal of Hydrogen Energy · 2026
- Numerical Simulation and Performance Evaluation of Blow Molded Polymeric Liner for 350 Bar Type‐4 Hydrogen Pressure Vessel With Experimental ValidationPolymer Engineering and Science · 2025
- Synergistic Enhancement of Mechanical, Thermal, and Hydrogen Barrier Properties of Nylon with PEI-GO-EVOH Nanocomposite CoatingsEnergy & Fuels · 2026
- Robust Yet Conductive Blend Anion Exchange Membranes for Hydrogen Production via PPO Reinforcement of Highly Functionalized Styrene-Butadiene-Based Ionomers.Membranes · 2026
- Advanced co-dispersed multi-phase nanocomposites for nuclear engineering: Mixed gamma attenuation, computational fast neutron moderation, and Monte Carlo simulation validation.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026