A Fictitious Domain Formulation Based on Hierarchical Model Reduction Applied to Drug‐Eluting Stents
Anna Ranno, Francesco Ballarin, Fabien Lespagnol, Paolo Zunino, Simona Perotto
Key points
From the paper's conclusion- To this aim, we introduce a variant of the fictitious domain (FD) formulation based on hierarchical model (HiMod) reduction for the numerical modeling of drug transport in a stented artery.
Abstract
The objective of this work is to extend the HiMod approach to geometrically irregular domains, such as domains containing small obstacles, and to assess the trade‐off between accuracy and computational efficiency, using the number of degrees of freedom (DOFs) as one measure of the latter. To this aim, we introduce a variant of the fictitious domain (FD) formulation based on hierarchical model (HiMod) reduction for the numerical modeling of drug transport in a stented artery. In more detail, the FD approach introduces a single computational domain for the stent and the lumen, the drug concentration at the stent–lumen interface being weakly imposed by using a reduced space of Lagrange multipliers. The HiMod reduction contains the computational cost of the simulation by combining, within a separation‐of‐variables framework, a finite‐element discretization along the direction associated with the blood flow with a modal expansion along the transverse direction. We compare the proposed FD‐HiMod approximation with a FD approach based on conforming and non‐conforming finite‐element (FD‐FEM) on an axisymmetric one‐ring benchmark configuration with constant advection, for different choices of boundary conditions at the lumen‐wall interface and for a diverse number of Lagrange multipliers. For a zero‐flux wall boundary condition and two multipliers, the FD‐HiMod discretization yields a relative ‐error of 1%–, while the non‐conforming FD‐FEM method gives an error of about 3%– for a comparable number of DOFs, ranging from to . The conforming FD‐FEM method achieves an error of approximately , but requires about DOFs. The advantage of the FD‐HiMod approach is confirmed also for a more challenging three‐ring configuration under representative coronary flow conditions, where it yields errors of approximately 10%–, compared with values up to for the non‐conforming FD‐FEM method. Although, this study is intended as a proof of concept, the results suggest that FD‐HiMod may represent a preferable alternative to the non‐conforming FD‐FEM approach, also in view of future assessments in more clinically relevant settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Statistical Shape Modeling Approach for the Derivation of a Data‐Driven Geometry‐Aware Lumped Arterial Stenosis ModelInternational Journal for Numerical Methods in Biomedical Engineering · 2026
- DiffStent: Surrogate Adjoint Differentiation for Stent Deployment in Anisotropic ArteriesarXiv · 2026
- Grid-Size Design Strategy for FEM–DEM Coupled Flow Simulations with Application to a Flow Diverter Stent ModelApplied Sciences · 2026
- Fully discrete second-order energy-stable HDG method for Carreau-type blood flows with applications to three-dimensional aneurysm hemodynamicsComputer Methods in Applied Mechanics and Engineering · 2026
- Investigation of Gold Nanoparticle‐Enhanced Blood Flow in a Porous Inclined Tapered Stenosed Artery under the Impact of Uniform Magnetic Field and Thermal RadiationAdvanced Theory and Simulations · 2025
- A data-driven framework to identify restenosis-prone regions in femoral arteries from geometric and inflow waveform parametersJournal of The Royal Society Interface · 2026