Quantitative MRI Relaxation Parameters for Hypoxia Assessment in 3D Cancer Cell Spheroids
Maryam Abarashi, Clara J. Fallone, Thomas A. Peterson, Yang Yang, Hokan Krowicki, Rodin Chermat, Elena Refet‐Mollof, Karl Riabowol,
Key points
From the paper's conclusion- These findings identify as the relaxation parameter most closely associated with hypoxia‐related changes in this controlled spheroid model and support its further evaluation as a quantitative MRI marker of tumor hypoxia.
Abstract
Tumor hypoxia is a major determinant of treatment resistance, yet non‐invasive imaging markers that reflect hypoxia‐associated changes remain limited. In this study, the associations of quantitative MRI relaxation parameters with size‐associated hypoxia were evaluated in three‐dimensional HCT116 tumor spheroids, in which hypoxia develops naturally as spheroids grow. Spheroids of four nominal diameters (400, 650, 800, and 1050 m) were generated in microfluidic chips and imaged simultaneously on a clinical 3 T scanner. , and were estimated from inversion‐recovery, multi‐echo spin‐echo, and multi‐echo gradient‐echo acquisitions using an in‐house fitting framework validated with a quantitative MRI system phantom, and was derived from and . Expression of carbonic anhydrase IX (CA‐IX), quantified by western blot, was used as a biological proxy for hypoxia. CA‐IX expression increased with spheroid size, with the same rank order on all three blots (). showed the strongest size‐dependent change, decreasing from 291 to 236 ms across the size groups (Kruskal–Wallis ; Kendall's ), and group‐mean decreased in close parallel with CA‐IX expression (Pearson's ). showed a weaker, non‐significant trend, and and were unchanged, as expected in an avascular model without deoxyhemoglobin. The association between and spheroid size was robust to the position of the chips in the scanner. Exploratory multivariable regression and principal component analysis indicated that combining parameters added little information beyond alone. These findings identify as the relaxation parameter most closely associated with hypoxia‐related changes in this controlled spheroid model and support its further evaluation as a quantitative MRI marker of tumor hypoxia.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Radiomics analysis of 3D spheroids captures irradiation-induced structural and textural changes.Scientific reports · 2026
- Development and Preclinical Evaluation of [68Ga]Ga-DOTA-L3: A Novel PET Tracer for Quantitative Imaging of Carbonic Anhydrase IX.Molecular pharmaceutics · 2026
- Hypoxia-induced drug-resistance bias 3D cancer spheroid drug screensAPL Bioengineering · 2026
- Activatable hypoxia magnetic resonance imaging for early stratification of radiotherapy response.Nanoscale horizons · 2026
- Theranostic nanoplatforms applications of 3D tumor spheroid models: progress, limitations, and future directionsHealth Nanotechnology · 2026
- IMG-30 Noninvasive Mapping of Tumor Cell Size Distribution Using Deep Learning and Susceptibility-Contrast MRINeuro-Oncology · 2026