Can Spleen T1 Mapping Be Used as a Marker of Adenosine Response in Cardiac MRI?
Sergio M. Solis‐Barquero, Ana Ezponda, Verónica Aramendía‐Vidaurreta, Marta Vidorreta, Marina Pascual, Gorka Bastarrika, Maria A. Fernández‐Seara
Key points
From the paper's conclusion- This work indicates that the splenic T1 value change has the potential to identify splenic switch‐off during adenosine stress CMR in a clinical population.
Abstract
Splenic switch‐off, defined as the visible reduction in splenic perfusion during adenosine stress, can be used as a marker of adequate adenosine response in cardiac stress MRI studies, which can be assessed after the study. Moreover, there is some evidence regarding the use of T1 mapping for the evaluation of splenic switch‐off during the study. The aim of this work is to further investigate splenic T1 mapping as a method for quantitatively assessing splenic switch‐off, given the limited existing data. Patients with suspected coronary artery disease were scanned at 1.5 T with the routine clinical protocol for stress perfusion cardiac magnetic resonance (CMR), including a T1 mapping sequence at rest and during adenosine stress. Visual assessment of first‐pass images was used as the reference standard for detecting splenic switch‐off. Semi‐quantitative analysis of splenic perfusion was performed based on the signal intensity curves and signal changes (ΔSI) were calculated. T1 maps were used to obtain T1 value changes in the spleen from rest to stress (ΔT1 spleen ). Statistical analysis was assessed using an align rank transform followed by a mixed analysis of variance, with Bonferroni corrected post hoc tests. A total of 74.5% ( n = 35/47) of analyzed patients experienced splenic switch‐off according to the visual assessment. Statistically significant differences were found in splenic T1 between rest and stress only in the switch‐off group ( p < 0.001), with lower T1 values during stress. There was significant positive weak correlation (ρ s = 0.37, p = 0.01) between splenic ΔT1 and ΔSI based on first‐pass. ROC curves demonstrated that ΔT1 spleen classified the failed switch‐off and positive switch‐off groups with a specificity of 75% and a sensitivity of 80% (AUC: 81.2%, 95% CI: 66.7%–95.8%). This work indicates that the splenic T1 value change has the potential to identify splenic switch‐off during adenosine stress CMR in a clinical population.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Splenic tissue alterations in ST-elevation myocardial infarction: determinants and prognostic implicationsEuropean Heart Journal - Cardiovascular Imaging · 2026
- Speckle-tracking echocardiographic strain parameters in cardiac magnetic resonance-confirmed myocarditis: associations with myocardial edema and subsequent left ventricular functional improvement.Journal of cardiovascular imaging · 2026
- Artificial intelligence-derived splenic response in cardiac positron emission tomography is associated with major adverse cardiovascular events: a multi-site study.Cardiovascular research · 2026
- Clinical stress markers vs. quantitative myocardial blood flow for assessing adequate hyperemia during stress CMREuropean Heart Journal · 2026
- Multiparametric CEST MRI for Time-Associated Characterization of Acute Ischemic Stroke: NOE (-3.5 ppm) Signal as a Potential Imaging Biomarker.Molecular imaging · 2026
- Evaluating the impact of passive driver position on image consistency and repeatability in 3.0T cardiac magnetic resonance elastography.Frontiers in radiology · 2026