Validation of a Novel, Low‐Cost, Portable MRI‐Compatible Exercise Device in Healthy Volunteers and Patients With Pulmonary Hypertension
Ruta Virsinskaite, James T. Brown, Tushar Kotecha, Darren Bower, Jennifer A. Steeden, Javier Montalt‐Tordera, Olivier Jaubert, Marianna Fontana,
Key points
From the paper's conclusion- We have created a simple, easy to use and affordable exercise device for the CMR environment.
Abstract
The value of exercise cardiovascular magnetic resonance (CMR) has been shown in many clinical scenarios. We have developed a novel MR‐compatible exercise device and aim to validate it against the reference standard MR‐conventional ergometer. The novel device consisted of two half‐pipes fixed to a wooden base, with participants wearing knee‐length socks with a 0.5 kg weight in each sock. Increased workload was achieved by increasing the rate of alternating leg flexion and extension in time with a bleep sound of increasing frequency. Twenty subjects (10 healthy volunteers, 10 patients with pulmonary arterial hypertension) performed two CMR‐augmented cardiopulmonary exercise tests (CMR/CPET) using the novel exercise device and a conventional ergometer in a randomised order. Comparing peak metrics elicited on both exercise devices, there was a moderate correlation in peak oxygen consumption (VO 2 , r = 0.86, p < 0.001), cardiac output (CO, r = 0.73, p < 0.001), stroke volume (SV, r = 0.90, p < 0.001), peak heart rate (HR, r = 0.65, p = 0.002) and peak arteriovenous oxygen content gradient (ΔavO 2 , r = 0.71, p < 0.001). However, all metrics were significantly lower with the novel device. Both devices were able to elicit statistically significant differences in VO 2 , HR and right ventricular ejection fraction (RVEF) between patients and healthy subjects ( p ≤ 0.04). We have created a simple, easy to use and affordable exercise device for the CMR environment. This may encourage greater dissemination of exercise CMR in clinical and research practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Minimum-workload exercise testing for the detection of exercise pulmonary hypertensionEuropean Heart Journal · 2026
- Real-time CMR combined with cardiopulmonary exercise testing enables integrated assessment of cardiac function during exercise.Frontiers in cardiovascular medicine · 2026
- Higher Respiratory Muscle Oxygen Cost of Breathing During Exercise in Heart Failure With Preserved Ejection FractionCHEST Journal · 2026
- CaReFit: Cost-Effective Cardiorespiratory Fitness Assessment Using Multimodal SensorsProceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · 2026
- Hemodynamic effects of cycle ergometry versus dynamic unilateral arm exercise during right heart catheterization: a prospective observational study.BMC pulmonary medicine · 2026
- Hybrid cardiac rehabilitation at anaerobic threshold reduces myocardial fibrosis and improves outcomes in HFrEF post-MI: a multicenter RCTEuropean Heart Journal · 2026