科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Frontiers in neuroscience2026-01-01

Radiofrequency bandwidth effects in direct saturation dynamic glucose enhanced MRI at 3T.

Patrick Michael Lehmann, Sajad Mohammed Ali, Nirbhay N Yadav, Anina Seidemo, Ronnie Wirestam, Pia Charlotte Sundgren, Emil Langensee Ljungberg, Linda Knutsson

一句话结论 · In one sentence

The use of longer RF pulses, within the 500 ms total saturation duration, improved estimation accuracy when employing a Lorentzian fit. This approach can be readily implemented without major modifications to the acquisition or post-processing protocol. These findings therefore provide a practical basis for future in vivo DS-DGE studies, as well as for other applications employing linewidth-sensitive Z-spectra approaches.

原始摘要(英文原文)· Original abstract
PURPOSE: Direct Saturation Dynamic Glucose Enhanced (DS-DGE) MRI is a novel technique that utilizes low B1 strength and short saturation pulse duration to measure the effect of enhanced T2 relaxation caused by the infusion of D-glucose, resulting in linewidth broadening of the direct water saturation (DS) signal in the water saturation spectrum (Z-spectrum). In this simulation-supported protocol optimization study, we investigated this approach for brain tumor applications, with particular emphasis on the design of the radiofrequency (RF) saturation pulses. Artifacts related to the bandwidth of the RF saturation pulses, affecting the linewidth derived from Lorentzian fitting of the DS resonance, were investigated. METHODS: In vivo DS-DGE MRI Z-spectra were analyzed using Lorentzian line-shape fitting. To support experimental findings, simulated Z-spectra were generated using Bloch-McConnell simulations implemented in Pulseq-CEST, covering a wide range of T1 and T2 relaxation times. Diverse RF saturation schemes were employed, varying in saturation duration, number of pulses, and pulse shape. The accuracy of Lorentzian fitting was assessed across these RF pulse configurations. RESULTS: RF pulses for a fixed total duration of 500 ms, with maximized individual pulse length, resulted in less sideband artifacts compared to using more pulses of shorter individual length. Choosing fewer than 5 pulses yielded Lorentzian linewidth estimates with a root-mean-square-error (RMSE) below 1 %. CONCLUSION: The use of longer RF pulses, within the 500 ms total saturation duration, improved estimation accuracy when employing a Lorentzian fit. This approach can be readily implemented without major modifications to the acquisition or post-processing protocol. These findings therefore provide a practical basis for future in vivo DS-DGE studies, as well as for other applications employing linewidth-sensitive Z-spectra approaches.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Radiofrequency bandwidth effects in direct saturation dynamic glucose enhanced MRI at 3T. — 科研速览 Science Skim