Fast Voxelwise SNR Estimation for Iterative MRI Reconstructions.
Onat Dalmaz, Daniel Abraham, Alexander R Toews, Akshay S Chaudhari, Kawin Setsompop, Brian A Hargreaves
Department of Electrical Engineering, Stanford University, Stanford, California, USA. · Department of Radiology, Stanford University, Stanford, California, USA.
Key points
From the paper's conclusion- PICO targets the exact covariance of fixed linear reconstructions and a first-order covariance for nonlinear reconstructions, providing a computationally efficient alternative to PMR. By reusing existing reconstruction primitives, it could help incorporate voxelwise noise maps into reconstruction workflows.
Abstract
PURPOSE: To develop a fast, general-purpose framework for voxelwise noise characterization in iterative MRI reconstructions, recovering the image-domain noise variance, the primary quantity from which SNR, g -factor, and related image-quality metrics are derived. The framework addresses both the intractability of closed-form formulas beyond Cartesian sampling and the long runtime of pseudo multiple replica (PMR). METHODS: A stochastic noise estimator is proposed that operates in the image domain by Probing the Image-space noise COvariance matrix (PICO) with random probe images. Complex random-phase probes attain minimum kurtosis and reduce estimator variance in the tested reconstruction. PICO was validated against analytical benchmarks and PMR references using Cartesian knee data ( R = 2 ), physical brain phantom data ( R = 2 , 3 , 4 ), in vivo non-Cartesian brain data ( R = 2 ), and compressed-sensing knee reconstructions ( R = 2 ). RESULTS: In Cartesian reconstructions, PICO accurately reproduced analytical SENSE g -factor maps. In non-Cartesian reconstructions, it achieved 1 % g -factor NRMSE ≈ 11 . 9 × faster than PMR in a phantom and ≈ 2 . 81 × faster in vivo, with the efficiency advantage persisting at higher acceleration. For compressed sensing, the Jacobian-based estimator produced noise maps consistent with PMR and computed them 1 . 84 × faster at equal sample counts. Agreement worsened at large added-noise amplitudes and moderate TV strengths. CONCLUSION: PICO targets the exact covariance of fixed linear reconstructions and a first-order covariance for nonlinear reconstructions, providing a computationally efficient alternative to PMR. By reusing existing reconstruction primitives, it could help incorporate voxelwise noise maps into reconstruction workflows.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Deep Learning Reconstruction for Accelerated Radial CEST MR Fingerprinting.ArXiv · 2026
- MR Optimum: A web-based open-source tool for standardized signal-to-noise ratio evaluation in MRI.Computer methods and programs in biomedicine update · 2026
- Empirical noise mapping guides optimal region-of-interest selection for accurate noise estimation in prostate DWI.Journal of applied clinical medical physics · 2026
- Low-spatial-frequency perception enhancing dynamic convolutional network for system matrix recovery in magnetic particle imaging.Medical physics · 2026
- Restoring Marcenko-Pastur noise estimation and denoising of diffusion MRI under common image reconstructionbioRxiv · 2026
- Highly Accelerating Joint Intracranial and Carotid Vessel Wall Imaging Using ESPIRiT-Driven Diffusion Model Reconstruction.Magnetic resonance in medicine · 2026