Abstract

PURPOSE: To improve deep learning-based QSM+qBOLD (QQ) oxygen extraction fraction (OEF) mapping by explicitly learning the temporal evolution of the multi-echo gradient-echo (mGRE) magnitude signal, whose decay encodes the tissue oxygenation that QQ-based OEF mapping depends on. METHODS: 3D multi-echo gradient echo images were acquired in 34 ischemic stroke patients with arterial spin labeling (ASL) and diffusion-weighted imaging (DWI). We developed QQ-S, a deep learning method that estimates OEF by inverting the QQ model. QQ-S extends QQ-NET by adding convolutional long short-term memory (ConvLSTM) modules to the encoder to process the mGRE echoes sequentially. To isolate the effect of this architectural change, both networks were trained with the same simulated data and training scheme including the loss function. OEF maps from QQ-S and QQ-NET were compared in simulation and ischemic stroke patients. RESULTS: In simulation, QQ-S provided more accurate OEF than QQ-NET, with lower mean absolute error (MAE) against the simulation ground truth: 3.43% vs. 5.03% in normal-appearing tissue and 4.88% vs. 10.60% in low-OEF lesions. In subacute stroke patients, where no ground truth is available, the lesion-to-contralateral OEF ratio was significantly lower with QQ-S than with QQ-NET (0.71 ± 0.26 vs. 0.81 ± 0.24; p < 0.001), suggesting more sensitive detection of lesion OEF, consistent with PET reports in the subacute phase. OEF in acute lesions and normal-appearing tissue was comparable between methods. CONCLUSION: By explicitly learning inter-echo signal evolution with ConvLSTM, QQ-S improves OEF accuracy over QQ-NET, offering a promising tool for assessing tissue viability from conventional mGRE data.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Improving Oxygen Extraction Fraction (OEF) Mapping From Integrated Quantitative Susceptibility Mapping and Quantitative Blood Oxygen Level Dependent Imaging (QSM+qBOLD, or QQ) by Learning Temporal Signal Evolution — Science Skim