Pulsed Off-Resonance Saturation for Macromolecular Proton Fraction-Weighted Contrast With Intrinsic Flow Attenuation.
Qianxue Shan, Zijian Gao, Chun Liu, Queenie Chan, Qiuyi Shen, Ziqiang Yu, Weitian Chen
Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Hong Kong, China. · Philips Healthcare, Hong Kong, China.
Key points
From the paper's conclusion- A novel MPF-weighted contrast imaging method using pulsed off-resonance MT preparation with intrinsic flow attenuation is proposed, providing a technical basis for future MPF-sensitive vessel wall imaging.
Abstract
PURPOSE: To develop a pulsed off-resonance magnetization transfer (MT) preparation module that achieves intrinsic flow attenuation while enabling efficient macromolecular proton fraction (MPF)-weighted contrast that specific to macromolecular pool. METHODS: In the proposed MPF-SPS (MPF-weighted contrast mapping using short pulsed saturation) approach, repetitive short off-resonance RF pulses are applied in conjunction with spoiler gradients, enabling simultaneous MT contrast generation in stationary tissue and intrinsic blood signal attenuation. An MPF-weighted relaxation rate, R mpfsps , is derived that is specific to the macromolecular pool and independent of the free water pool. An off-resonance Extended Phase Graph (EPG) framework incorporating MT effects was developed for efficient parameter optimization. The proposed approach is validated with EPG-based two-pool simulations, phantom, and in vivo brain studies at 3.0 T. RESULTS: Simulations showed that the off-resonance EPG-MT framework closely agrees with two-pool Bloch-McConnell simulations while requiring substantially less computation time. This efficient framework was used to optimize the sequence parameters, confirming that intrinsic flow attenuation effectively reduces partial-volume effects caused by intravascular signal contamination. Both simulations and phantom experiments demonstrated that MPF-SPS provides R mpfsps maps that are insensitive to free-water-pool parameters. In vivo brain imaging further demonstrated that the proposed method generates R mpfsps maps with MPF-weighted contrast and intrinsic flow attenuation. CONCLUSION: A novel MPF-weighted contrast imaging method using pulsed off-resonance MT preparation with intrinsic flow attenuation is proposed, providing a technical basis for future MPF-sensitive vessel wall imaging.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantitative proton density mapping with data-driven reception profile correction derived from macromolecular proton fraction.medRxiv : the preprint server for health sciences · 2026
- A deep learning pipeline for liver macromolecular proton fraction quantification without subject-specific B1 acquisition using spin-lock MRI.Quantitative imaging in medicine and surgery · 2026
- Optimizing an Automated Processing Pipeline for Regional Macromolecular Proton Fraction and Volume Measurements in the Brain.bioRxiv : the preprint server for biology · 2026
- Retrospective macromolecular pool fraction mapping from conventional clinical MRI: a physics-guided self-supervised deep learning frameworkarXiv · 2026
- Sensitivity and Cellular Labelling Performance of Magnetically Fractionated SPIONs for Multimodal MRI/MPI Imaging.Nanomaterials (Basel, Switzerland) · 2026
- Narrowband isotropic magnetic particle imaging with FFL-parallel excitation.Physics in medicine and biology · 2026