Combining Cartesian and Non-Cartesian Acceleration Techniques With SPARKLING for 1 mm Isotropic Whole-Brain MPRAGE in a Minute.
Chaithya Giliyar Radhakrishna, Aurélien Massire, Blanche Bapst, Alexandre Vignaud, Philippe Ciuciu
CEA, NeuroSpin, CNRS, Université Paris-Saclay, Gif-sur-Yvette, France. · Siemens Healthcare SAS, Courbevoie, France.
Key points
From the paper's conclusion- By jointly leveraging PI and CS, GoLF-SPARKLING achieves high acceleration factors that enable sub-minute, high-quality anatomical MRI. This translates into greater clinical throughput and more reliable imaging in patients who are challenging to scan.
Abstract
PURPOSE: T 1 -weighted MPRAGE remains a cornerstone of clinical anatomical imaging, yet its long acquisition times constrain routine use. Established acceleration techniques, namely Parallel Imaging (PI) and Compressed Sensing (CS), tend to introduce substantial noise and blurring when pushed to high acceleration factors. Although they rely on fundamentally different redundancies, combining them synergistically remains an open challenge. METHODS: The GoLF-SPARKLING framework was extended to jointly exploit two acceleration mechanisms: PI-based uniform undersampling in the central k-space region and variable-density CS at the periphery, with independent acceleration factors in each zone. To preserve smooth signal evolution throughout the inversion-recovery period and avoid modulation artifacts, the acquisition trajectory was reordered accordingly. The resulting method was evaluated prospectively in vivo at 1 mm isotropic resolution and benchmarked against Wave-CAIPI and Poisson-disk sampling as respective PI and CS baselines. RESULTS: The proposed hybrid approach produced sharper, less noisy, and more stable whole-brain images in approximately 1 min than either acceleration strategy alone. Purely PI-based reconstructions were degraded by high g-factor noise, while exclusively CS-based reconstructions exhibited pronounced blurring. Furthermore, this method yielded lower average volumetric errors in downstream automated brain segmentation than state-of-the-art acceleration techniques, demonstrating its clinical utility. CONCLUSION: By jointly leveraging PI and CS, GoLF-SPARKLING achieves high acceleration factors that enable sub-minute, high-quality anatomical MRI. This translates into greater clinical throughput and more reliable imaging in patients who are challenging to scan.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of Compressed Sensing Accelerated Magnetization Prepared Rapid Acquisition Gradient Echo for Fast and Reliable Brain Volume Measurement.Tomography (Ann Arbor, Mich.) · 2026
- Whole-Brain Cerebral Microvascular Pulsatility Imaging Using Dynamic pCASL MRI With Segmented Stack-of-Stars Golden-Angle Radial Acquisition.Magnetic resonance in medicine · 2026
- Achieving Ultra-High Acceleration Rates in 7T MRI Using Combined Controlled Aliasing in Parallel Imaging and Compressed Sensing with Deep-Learning–Based Image ReconstructionAmerican Journal of Neuroradiology · 2026
- Motion-robust high-resolution 3D-GRASE pseudo-continuous ASL perfusion imaging at 3TmedRxiv · 2026
- Localized Quadratic RF Encoded Spin-Echo With Spiral-PRIME Reconstruction: A Practical Alternative to 3D FSE for High-Resolution Volumetric Brain MRI.Magnetic resonance in medicine · 2026
- Acceleration-dependent variability in simultaneous T1/T2 mapping with a hybrid (mixed) sequence: a phantom comparison of SENSE, compressed sensing, and deep learning reconstructions.Magnetic resonance imaging · 2026