Whole-Ventricle Cardiac Cine MRI in a Single Breath-Hold With Slice- and Time-Dependent Deep Image Prior at 0.55T.
Rafael de la Sotta, Tabita Catalán, Carlota Rivera, Francisco Sahli Costabal, Rene M Botnar, Claudia Prieto
Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile.
Key points
From the paper's conclusion- Purpose To develop a whole‐ventricle cardiac cine MRI radial acquisition at 0.55T in a single breath‐hold scan of approximately 12–15 s, reconstructed using a novel self‐supervised slice and time‐dependent deep image prior (ST‐DIP) neural network.
Abstract
PURPOSE: To develop a whole-ventricle cardiac cine MRI radial acquisition at 0.55T in a single breath-hold scan of approximately 12-15 s, reconstructed using a novel self-supervised slice and time-dependent deep image prior (ST-DIP) neural network. METHODS: A whole-ventricle cardiac cine MRI at 0.55T is acquired in a single breath-hold by collecting eight slices (1.5 s per slice) and reconstructing them jointly using ST-DIP. Acquisition uses a tiny golden angle radial trajectory and a balanced steady-state free precession (bSSFP) readout. Reconstruction uses a frequency-weighted consistency loss in the frequency domain and total variation regularization in the image domain, sharing the same network weights for all slices. The proposed approach was tested in 10 healthy subjects and was compared with time-dependent deep image prior (TD-DIP) and conventional reconstruction methods. RESULTS: ST-DIP achieves an edge sharpness of 1.15 ± 0.32 [ pixel - 1 ] at the septum, slightly higher than TD-DIP ( 1.08 ± 0.21 [ pixel - 1 ]) and significantly higher than GRASP ( 0.72 ± 0.13 [ pixel - 1 ]). The LVEF obtained with ST-DIP was 58.7 % ± 3.7 % , comparable to the 15-s-per-slice radial reference scan ( 59.1 % ± 5.1 % ). ST-DIP reconstructed 8 slices simultaneously in 16 ± 2 min, whereas TD-DIP, GRASP, and SENSE required sequential reconstruction times of 45 ± 4 , 12 ± 2 , and 3 min, respectively. CONCLUSION: ST-DIP enables whole-ventricle cine imaging in a single breath-hold and reconstruction of high-quality cine images at 0.55T, outperforming conventional methods in image quality while providing comparable LVEF to a 15-s-per-slice radial reference cine scan.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Patch-Based Diffusion Reconstruction for Accelerated Cardiac CinearXiv · 2026
- Beyond Training from Scratch: Foundation Models for Data-Efficient and Generalizable Cardiac MRI ReconstructionarXiv · 2026
- Accelerated Cardiac MRI Using Deep Learning Cine Imaging: Validation in Pediatric Patients both with and without Congenital Heart Disease.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2026
- MRI-Guided Reslice-Refined Cross-Slice SDF Reconstruction of the Left Ventricle from Cardiac MRI with Sparse Axial SupervisionarXiv · 2026
- Multi‐Frame Image Registration for Automated Ventricular Function Assessment in Single Breath‐Hold Cine MRI Using Limited LabelsMagnetic Resonance in Medicine · 2025
- SSCA-DIPNet: Structured Sparse and Channel-Attentive Deep Image Prior Network for Highly-Accelerated MRI.Biomedical physics & engineering express · 2026